Frequency Tests
240
MAX-635G
Locator Tone
Locator Tone
When
Locator Tone
is selected from the
Frequency Tests
menu, a 577 Hz
signal and a 983 Hz alternating signal are sent separately for 200 ms each.
The sequence of this tone is repeated continuously until you stop the test.
Sinusoidal waveform is used to generate these signals.
Tone
The
Tone
function allows you to set the
Tone Power
and generate a pulsed
tone on the line to trace a cable pair at the far end.
Current Group
is the current test group name, for
example
Frequency Tests
.
Current Test
displays the test being measured.
Here you can switch to another test from the given
list. However, this action will terminate the
ongoing measurement test.
Tone Power
allows you to select either low or
high power for the
Locator Tone
.
Tone Frequencies
displays the frequencies of the
Locator Tone
.
Termination Resistance
is a read-only value of
600
Ω
.
Result
displays the
Elapsed Time
the locator tone is being sent.
Test Status
displays the current state of measurement or an error
message.
Summary of Contents for MAX-635G
Page 1: ...User Guide Copper and G fast VDSL2 ADSL2 Multi play Test Set MAX 635G www EXFO com ...
Page 10: ......
Page 26: ......
Page 162: ......
Page 218: ......
Page 270: ...TDR 260 MAX 635G Continuous Examples of Common Faults Short Fault ...
Page 271: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 261 Continuous Open ...
Page 272: ...TDR 262 MAX 635G Continuous Bridged Tap ...
Page 273: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 263 Continuous Splice Joint ...
Page 274: ...TDR 264 MAX 635G Continuous Peak Function ...
Page 275: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 265 Continuous Dual Trace View ...
Page 276: ...TDR 266 MAX 635G Continuous Load Coil ...
Page 290: ......
Page 336: ......
Page 414: ......
Page 424: ......
Page 432: ......
Page 438: ......
Page 444: ......