RFL
284
MAX-635G
Separate Good Pair
Separate Good Pair
The RFL
Separate Good Pair
or 4-wire test allows you
to determine the distance to a short, ground, or
battery cross on a faulty cable conductor using two
separate good cable conductors.
Connect a strap from the faulted wire to both
conductors of the good pair.
The
connection diagram
shows you how to
connect the cables to the unit.
When FED is
Enabled
on the
FED Setup
page, the
Confirmation
window pops up displaying how to
connect your cables at the beginning of the test.
The FED allows you to remotely place a
strap
(to
short together) the A1/A/B (T1/T/R) at the far end
for 4-wire RFL.
The
Confirmation
diagram uses graphic and
textual components.
Proceed
button closes the hookup diagram prompt and starts the
test.
Cancel
button closes the hookup diagram prompt only.
Note:
Unlike 2-wire RFL, G/E on the FED is not grounded (on the FED side).
Note:
Results are more accurate but less forgiving than a 2-wire setup because
the 4-wire setup requires you to connect the faulted wire conductor to the
Ring (red) jack only.
Summary of Contents for MAX-635G
Page 1: ...User Guide Copper and G fast VDSL2 ADSL2 Multi play Test Set MAX 635G www EXFO com ...
Page 10: ......
Page 26: ......
Page 162: ......
Page 218: ......
Page 270: ...TDR 260 MAX 635G Continuous Examples of Common Faults Short Fault ...
Page 271: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 261 Continuous Open ...
Page 272: ...TDR 262 MAX 635G Continuous Bridged Tap ...
Page 273: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 263 Continuous Splice Joint ...
Page 274: ...TDR 264 MAX 635G Continuous Peak Function ...
Page 275: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 265 Continuous Dual Trace View ...
Page 276: ...TDR 266 MAX 635G Continuous Load Coil ...
Page 290: ......
Page 336: ......
Page 414: ......
Page 424: ......
Page 432: ......
Page 438: ......
Page 444: ......