Separate Good Pair
If the test reports that it cannot detect the strap when the measured
loop resistance is >10 k ohms, this may mean:
There is no strap connected.
There is a strap, but the cable is too long and has a loop resistance
>10 k ohms.
There is a strap, but there is a high resistance fault or open in the
cable.
The connection (leads or strap) may be faulty.
The resistance test may be used to troubleshoot this problem.
Fault Status
displays the status of the RFL test.
Test Status
displays the current state of measurement or an error
message.