RFL
Copper and G.fast/VDSL2/ADSL2+ Multi-play Test Set
291
RFL Cable Setup
RFL Cable Setup
The
Cable Setup
page allows you to set cable
parameters for an RFL test. Settings are shared by
Single Pair
,
Separate Good Pair
, and
K-Test
. Changes
done in
Cable Setup
for one test are reflected in all.
No. of Cable Sections
allows you to set the
number of consecutive cable sections, to a
maximum of 5. If unknown, set the number to 1.
Cable Type
# displays the number of a cable
section set above, ID, Cable Name and Fill, and
allows you to select an entry (with its associated
parameters) from the current Cable Book, to use
for testing. The selection is not saved when leaving the test. The
current Cable Book entry is shown by default.
Resistance
specifies a value for the resistance constant of the cable in
each section.
Section Length
allows you to specify the cable length of each section.
If the cable length is unknown, specify 0 and the RFL test will measure
the length.
Load Coil
allows you to set the detection of the presence of load coils
to either
Yes
or
No
.
Cable Temperature
allows you to change the temperature of the cable
under test in either
°F
or
°C
.
Summary of Contents for MAX-635G
Page 1: ...User Guide Copper and G fast VDSL2 ADSL2 Multi play Test Set MAX 635G www EXFO com ...
Page 10: ......
Page 26: ......
Page 162: ......
Page 218: ......
Page 270: ...TDR 260 MAX 635G Continuous Examples of Common Faults Short Fault ...
Page 271: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 261 Continuous Open ...
Page 272: ...TDR 262 MAX 635G Continuous Bridged Tap ...
Page 273: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 263 Continuous Splice Joint ...
Page 274: ...TDR 264 MAX 635G Continuous Peak Function ...
Page 275: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 265 Continuous Dual Trace View ...
Page 276: ...TDR 266 MAX 635G Continuous Load Coil ...
Page 290: ......
Page 336: ......
Page 414: ......
Page 424: ......
Page 432: ......
Page 438: ......
Page 444: ......