Copper Auto Tests
316
MAX-635G
User Auto Test
VOP
is the velocity of propagation defined as m/
μ
sec (meters per
microsecond), a ratio, or percentage of the speed of light for the cable.
Cable Temperature
is the temperature of the cable under test in either
°F
or
°C
.
DRP Result
The
Data Rate Prediction (DRP)
is a software option
and requires that
WB Attenuation
and
WB PSD Noise
tests are selected to enable the
DRP
test. When
enabled, the page displays the predicted maximum
Downstream
and
Upstream
data rates.
If a calculation is not possible, the calculated
bandwidth data is replaced by a message. It states that
the DRP cannot be completed due to low bandwidth
settings in the Noise PSD and/or Attenuation tests; and
that with the current settings, you can calculate rates
up to a certain
highest possible
Technology
, listed as
follows.
If the Noise PSD and/or Attenuation bandwidth are:
< 1.1 MHz then no
Technology
applies.
1.1 MHz then ADSL or ADSL2.
2.2 MHz, 8 MHz, or 12 MHz then ADSL, ADSL2, or ADSL2+.
17 MHz or 30 MHz then ADSL, ADSL2, ADSL2+, or VDSL2-17a.
35 MHz then all technologies apply.
Summary of Contents for MAX-635G
Page 1: ...User Guide Copper and G fast VDSL2 ADSL2 Multi play Test Set MAX 635G www EXFO com ...
Page 10: ......
Page 26: ......
Page 162: ......
Page 218: ......
Page 270: ...TDR 260 MAX 635G Continuous Examples of Common Faults Short Fault ...
Page 271: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 261 Continuous Open ...
Page 272: ...TDR 262 MAX 635G Continuous Bridged Tap ...
Page 273: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 263 Continuous Splice Joint ...
Page 274: ...TDR 264 MAX 635G Continuous Peak Function ...
Page 275: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 265 Continuous Dual Trace View ...
Page 276: ...TDR 266 MAX 635G Continuous Load Coil ...
Page 290: ......
Page 336: ......
Page 414: ......
Page 424: ......
Page 432: ......
Page 438: ......
Page 444: ......