Running DSL/IP Tests and Viewing Results
Copper and G.fast/VDSL2/ADSL2+ Multi-play Test Set
375
WAN Status
WAN Status
The
WAN Status
tab allows you to view the status information of the
connection between the WAN port of the unit and the ISP (internet service
provider). For
Manual Test
, you can also select which triple-play test you
want to run or view.
WAN Access
specifies the encapsulation method
used by the network and consists of the following
types:
PPPoE
is point-to-point protocol over
Ethernet.
PPPoA
is point-to-point protocol over ATM.
DHCP
is Dynamic Host Control Protocol
which is used to dynamically assign an IP
address for the client node on the network.
IPv6 (DHCP)
is equivalent to the above but for
Internet Protocol version 6 vs IPv4.
Static IP
is the current location assigned by the service provider or
user.
IPoA
stands for classical Internet Protocol over ATM.
WAN Status
value changes as per the WAN state of the current test. For
Manual Test
, the following states may be displayed:
Idle
- if WAN setup for the selected
Test
is different from the one
running and
Login
button is not activated.
Disconnected
- if WAN setup for the selected
Test
is different from
the one running and this test had WAN connected before and
stopped.
Connecting
or
Connected
- if current selected test is running.
Assigned IP
displays IPv4 address information assigned to the unit that
is connected to the network.
Summary of Contents for MAX-635G
Page 1: ...User Guide Copper and G fast VDSL2 ADSL2 Multi play Test Set MAX 635G www EXFO com ...
Page 10: ......
Page 26: ......
Page 162: ......
Page 218: ......
Page 270: ...TDR 260 MAX 635G Continuous Examples of Common Faults Short Fault ...
Page 271: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 261 Continuous Open ...
Page 272: ...TDR 262 MAX 635G Continuous Bridged Tap ...
Page 273: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 263 Continuous Splice Joint ...
Page 274: ...TDR 264 MAX 635G Continuous Peak Function ...
Page 275: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 265 Continuous Dual Trace View ...
Page 276: ...TDR 266 MAX 635G Continuous Load Coil ...
Page 290: ......
Page 336: ......
Page 414: ......
Page 424: ......
Page 432: ......
Page 438: ......
Page 444: ......