Maintenance
418
MAX-635G
Battery
Battery
The MaxTester is equipped with a Lithium Polymer battery.
When fully charged, the battery should provide between 3 and 10 hours
(for the single battery) and 6 to 20 hours (for the dual battery) of power
depending on different factors such as: type of tests performed, display
backlight level, and connected accessories.
Note:
When the battery level is very low, tests cannot be performed. Plug in the
AC/DC adapter for continued operation and to recharge the battery.
However, the charge speed will be reduced. Should the voltage detection
beeper sound when the unit is plugged in, remove the AC/DC adapter.
To maximize the battery power of the MaxTester:
1.
Lower the display backlight level using the application found in
Display and Language
in the
System
Settings
, when the unit is used
under low to medium light conditions.
2.
Disconnect any unused USB or SD accessories.
3.
Quit any running tests when the MaxTester is not in use.
4.
Whenever possible, put the unit in suspend mode by pressing until
the suspend notification sound plays, about 2 seconds.
5.
When not in use, turn the unit off by pressing for at least 4 seconds.
If you need to store your MaxTester for an extended period of time, place it
at room temperature in a clean and dry area, and ensure the unit’s battery
is charged at around 50 % of its capacity. Every three months during the
W
ARNING
Recharge the battery using only the MaxTester and with the
battery properly installed in the unit.
Never open the battery back panel of the MaxTester without
reading the
Replacing the Battery
section in this chapter.
Summary of Contents for MAX-635G
Page 1: ...User Guide Copper and G fast VDSL2 ADSL2 Multi play Test Set MAX 635G www EXFO com ...
Page 10: ......
Page 26: ......
Page 162: ......
Page 218: ......
Page 270: ...TDR 260 MAX 635G Continuous Examples of Common Faults Short Fault ...
Page 271: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 261 Continuous Open ...
Page 272: ...TDR 262 MAX 635G Continuous Bridged Tap ...
Page 273: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 263 Continuous Splice Joint ...
Page 274: ...TDR 264 MAX 635G Continuous Peak Function ...
Page 275: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 265 Continuous Dual Trace View ...
Page 276: ...TDR 266 MAX 635G Continuous Load Coil ...
Page 290: ......
Page 336: ......
Page 414: ......
Page 424: ......
Page 432: ......
Page 438: ......
Page 444: ......