Setting Up Copper Tests
Copper and G.fast/VDSL2/ADSL2+ Multi-play Test Set
75
Cable Book
Capacitance T/R to GND/A/B to E
specifies a value for the capacitance
per length to ground constant.
Resistance
specifies a value for the resistance constant of the cable.
Attenuation @ 300 kHz
specifies a value for the reduction in signal
strength or insertion loss of the cable.
VOP
is the velocity of propagation for the cable defined in m/
μ
sec
(meters per microsecond), and as a ratio and percentage of the speed
of light.
Temperature
specifies the temperature of reference at which all cable
parameters have been measured, in either F (Fahrenheit) or C
(Celsius) units. The measurement units are updated based on the
Temperature
settings in
Setup
/
Application Settings
/
Standard
.
To view and modify the cable details:
1.
Press the up/down arrow keys to highlight the desired parameter.
2.
Press the left/right arrow keys to view and select the options.
OR
3.
Press
on a value to open a list box of options and use the navigation
keys to scroll through.
4.
Press
to confirm the value.
5.
Press the
Accept
function key to update the cable details with your
changes.
Summary of Contents for MAX-635G
Page 1: ...User Guide Copper and G fast VDSL2 ADSL2 Multi play Test Set MAX 635G www EXFO com ...
Page 10: ......
Page 26: ......
Page 162: ......
Page 218: ......
Page 270: ...TDR 260 MAX 635G Continuous Examples of Common Faults Short Fault ...
Page 271: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 261 Continuous Open ...
Page 272: ...TDR 262 MAX 635G Continuous Bridged Tap ...
Page 273: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 263 Continuous Splice Joint ...
Page 274: ...TDR 264 MAX 635G Continuous Peak Function ...
Page 275: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 265 Continuous Dual Trace View ...
Page 276: ...TDR 266 MAX 635G Continuous Load Coil ...
Page 290: ......
Page 336: ......
Page 414: ......
Page 424: ......
Page 432: ......
Page 438: ......
Page 444: ......