Setting Up Copper Tests
84
MAX-635G
Application Settings
Standard
The
Standard
tab allows you to set unit parameter
values composed of the following:
Standard Selection
Standard
allows you to specify if the copper tests
should conform to the
ITU
(International
Telecommunications) or
ANSI
(American National
Standards Institute) standard.
Note:
Selecting the
Standard
resets the default
Measurement Units
,
Label Customization
, and
Test
Parameters Preset
for the page.
Measurement Units
Distance
lists the measurement units for distance in feet or meters.
Temperature
lists the measurement units for temperature in
F
(Fahrenheit) or
C
(Celsius).
Level
lists the units of power level in dBm or dBRN.
Capacitance
lists the units of capacitance for Tip and Ring in
nF/km
or
nF/mi
.
Resistance
lists the units for resistance in
Ω
/km
or
Ω
/mi
.
Attenuation
lists the units for the reduction in signal strength or
insertion loss of the cable, in
dB/km
or
dB/mi
.
Power Spectral Density
(PSD) lists the units to measure the noise
energy at a point in a noise spectrum. Units are dependent on the
previously selected
Level
.
Summary of Contents for MAX-635G
Page 1: ...User Guide Copper and G fast VDSL2 ADSL2 Multi play Test Set MAX 635G www EXFO com ...
Page 10: ......
Page 26: ......
Page 162: ......
Page 218: ......
Page 270: ...TDR 260 MAX 635G Continuous Examples of Common Faults Short Fault ...
Page 271: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 261 Continuous Open ...
Page 272: ...TDR 262 MAX 635G Continuous Bridged Tap ...
Page 273: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 263 Continuous Splice Joint ...
Page 274: ...TDR 264 MAX 635G Continuous Peak Function ...
Page 275: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 265 Continuous Dual Trace View ...
Page 276: ...TDR 266 MAX 635G Continuous Load Coil ...
Page 290: ......
Page 336: ......
Page 414: ......
Page 424: ......
Page 432: ......
Page 438: ......
Page 444: ......