Setting Up Copper Tests
90
MAX-635G
Application Settings
Buzzer
The
Buzzer
is a built-in, continuous warning system to
detect hazardous voltage levels on the line/test leads.
The tab allows you to configure values for the buzzer
settings. However, due to the risk of electrical shocks,
the MaxTester detects high voltages on any pair of
leads without user intervention.
Buzzer Threshold Voltage
allows you to
configure the hazardous voltage level from 70 to
150 volts.
Hush Time
allows you to configure the hush
timeout from 1 to 15 minutes.
Hush Buzzer
button mutes the sounding buzzer.
Note:
Upon raising the hazardous voltage flag, the MaxTester opens the relays
and you will have to press Start/Stop on the keypad to re initialize the unit.
In case the voltage is still too high, the MaxTester will open the relays once
again preventing any damage to the equipment. If not, the test will start
normally.
To set the buzzer settings:
1.
Use the up/down arrow keys to select the desired parameter.
2.
Press
on an entry to open the alphanumeric editor screen and use
the navigation keys to scroll through.
3.
Press
to confirm each value.
Summary of Contents for MAX-635G
Page 1: ...User Guide Copper and G fast VDSL2 ADSL2 Multi play Test Set MAX 635G www EXFO com ...
Page 10: ......
Page 26: ......
Page 162: ......
Page 218: ......
Page 270: ...TDR 260 MAX 635G Continuous Examples of Common Faults Short Fault ...
Page 271: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 261 Continuous Open ...
Page 272: ...TDR 262 MAX 635G Continuous Bridged Tap ...
Page 273: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 263 Continuous Splice Joint ...
Page 274: ...TDR 264 MAX 635G Continuous Peak Function ...
Page 275: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 265 Continuous Dual Trace View ...
Page 276: ...TDR 266 MAX 635G Continuous Load Coil ...
Page 290: ......
Page 336: ......
Page 414: ......
Page 424: ......
Page 432: ......
Page 438: ......
Page 444: ......