Multimeter Tests
94
MAX-610
Voltage
Voltage
The
Voltage
test detects AC RMS and DC voltages in the line and allows you
to measure AC/DC voltages and
Frequency
on A/B/E or T/R/G depending
on the selected
Standard
in
Setup
/
Application Settings
.
Snapshot
The voltage
Snapshot
shows measured volts for each
lead combination. The parameters are as follow:
Current Group
is the current test group name, for
example
Multimeter
.
Current Test
displays the test being measured.
Here you can switch to another test from the given
list. However, this action will terminate the
ongoing measurement test.
Selected Pair
allows you to select
All Pairs
or a
single wire pair for measurement.
Termination Resistance
defines how much
resistance the tester uses to connect to the line and measure voltages.
Threshold Settings
button opens a new page that allows you to set the
AC/DC voltage thresholds for each pair.
Result
displays a snapshot of the pass/fail status, volts and frequency
(Hz) values for each continuous AC/DC pair.
Test Status
displays the current state of measurement or an error
message.