Multimeter Tests
96
MAX-610
Voltage
Continuous AC Page
The
Continuous AC
function measures each pair,
displaying and updating results in
real time
, until you
stop the test. The last valid results then remain
displayed.
Continuous AC
and
Continuous DC
are run
synchronously.
Press Start/Stop on the keypad to run the test.
Current Group
is the current test group name, for
example
Multimeter
.
Current Test
displays the test being measured.
Here you can switch to another test from the given list. However, this
action will terminate the ongoing measurement test.
Selected Pair
allows you to select
All Pairs
or a single wire pair for
measurement.
Termination Resistance
defines how much resistance the tester uses
to connect to the line and measure voltages.
Threshold Settings
button opens a new page that allows you to set the
AC voltage thresholds for each pair.
Result
displays a snapshot of the pass/fail status, volts and frequency
(Hz) values for each continuous AC pair.
Test Status
displays the current state of measurement or an error
message.