SmartR™ Features
130
MAX-610
Pair Detective
The previous 2 parameters have 2 modes of operation:
Auto
is the default mode upon loading the test page. TDR
automatically optimizes the test parameters and scans each band
individually looking for one
Largest Event
in each band (if any).
Range
and
Gain
are updated to reflect optimized TDR settings.
Once results are displayed, TDR switches to manual mode. The
test keeps running until you press Start/Stop.
Manual
mode allows you set the test parameters to be used as
inputs for the TDR measurements.
Note:
If either of the above 2 test parameters are set to Auto, respective
parameter values will be updated by TDR test.
Pulse Width
is a non-editable value that is updated dependent on
whether the parameters are set to
Auto
or manual.
Cable Setup
button opens a new page that allows you to set the
Cable
Parameters
for the
Current Test
.
Select Graph
button changes to
Graph Selected
when pressed and
opens a new selection of function keys which allow you to maneuver
the graph as follows:
Cursor
- press the left/right arrow keys to decrease/increase the
values by moving the cursor. Press and hold the left/right arrow
keys to accelerate the cursor. Press
to recall the cursor and
place it in the middle of the current x-axis limits.
Zoom
references the middle of the x/y axis and
not
the cursor
position. Press the arrow keys as follows:
Right = x-axis zoom in.
Left = x-axis zoom out.
Up = y-axis zoom in.
Down = y-axis zoom out.