SmartR™ Features
136
MAX-610
FaultMapper
Open and the distance to Open is displayed and represented using X in
the graph.
Test Status
displays the current state of measurement or an error
message.
To select the parameter values:
1.
Press the up/down arrow keys to highlight the desired parameter.
2.
Press the left/right arrow keys to view and select the options.
OR
3.
Press
on a value to open a list box of options.
4.
Press
to confirm the value.
Cable Setup
The
Cable Setup
page allows you to set the
Cable
Type
,
Cable Length
, and
Cable Temperature
for the
FaultMapper test. All other
Cable Parameters
are read
only and correspond to the current cable book entry
as selected in
Setup
/
Cable Book
/
Cable Details
page.
Cable Type
allows you to select a cable entry
(with its associated parameters) from the current
Cable Book
, to use for testing. The selection is not
saved when leaving the test. The current
Cable
Book
entry is shown by default.
Cable Fill
read-only entry is the type of material
the cable is filled with:
Aircore
,
Jelly
,
Pulp
,
5 PR
,
or
2 PR
.
Capacitance T-R
/
A-B
read-only entry is a value for the capacitance per
length constant.
Capacitance T/R to GND
/
A/B to E
read-only entry is a value for the
capacitance per length to ground constant.