SmartR™ Features
MaxTester Copper Test
137
FaultMapper
Attenuation @ 300 kHz
read-only entry is a value for the reduction in
signal strength or insertion loss of the cable.
Velocity of Propagation
read-only entry is the velocity of propagation
for the cable as a ratio of the speed of light.
Resistance
read-only entry is a value for the resistance constant of the
cable.
Cable Length
allows you to set the length of the cable for more
accurate results.
Cable Temperature
allows you to change the temperature of the cable
under test in either degree C or F.
To select the parameter values:
1.
Press the up/down arrow keys to highlight the desired parameter.
2.
Press the left/right arrow keys to view and select the options.
OR
3.
Press
on a value to open a list box of options or the alphanumeric
editor screen and use the navigation keys to scroll through.
4.
Press
to confirm the value.
TDR
The FaultMapper
TDR
function provides a shortcut to
the TDR test. A dialogue box opens, warning that you
are about to leave the
FaultMapper
test. TDR results
captured while running FaultMapper will be available
upon loading TDR. Please go to
information on this test.