SmartR™ Features
138
MAX-610
FaultMapper
FaultMapper Result Details
The
Result Details
read-only page displays the test
results in text and graphical format.
Test Identification
is the name of the test, for
example
FaultMapper
.
Cable Setup
button opens a new page displaying
the cable parameters of the test. Use the left/right
arrows to select the button and press
to open
the page.
Result
displays the cable fault details.
Note:
Some displayed resistive faults may be
effective
faults.
For example if a strap is present, a T-G short may be shown twice: first as a
T-G short and second as an
effective
R-G short. In such cases, the
resistance shown is the resistance that would be measured using a
multimeter.
Estimated Length
displays the cable length when the cable is open.
Fault Status
displays the number of faults detected (or
No fault
detected
) after running the test.