Frequency Tests
MaxTester Copper Test
195
Locator Tone
Locator Tone
When
Locator Tone
is selected from the
Frequency Tests
menu, a 577 Hz
signal and a 983 Hz signal are sent separately for 200 ms each. The
sequence of this tone is repeated continuously until you stop the test.
Sinusoidal waveform is used to generate these signals.
Tone
The
Tone
function allows you to set the
Tone Power
and generate a pulsed
tone on the line to trace a cable pair at the far end.
Current Group
is the current test group name, for
example
Frequency Tests
.
Current Test
displays the test being measured.
Here you can switch to another test from the given
list. However, this action will terminate the
ongoing measurement test.
Tone Power
allows you to select either low or
high power for the
Locator Tone
.
Tone Frequencies
displays the frequencies of the
Locator Tone
.
Termination Resistance
is a read-only value of
600
Ω
.
Result
displays the
Elapsed Time
the locator tone is being sent.
Test Status
displays the current state of measurement or an error
message.