Copper Auto Tests
MaxTester Copper Test
225
POTS Auto Test
Phone Book Parameters
:
Phone Book Group
allows you to select the
Group #
from a list of
phone book groups that include mW tone entries.
Milliwatt Tone Entry
displays at least 1 mW tone entry number
from the selected
Phone Book Group
.
Quiet Line Entry
displays the quiet line entry number from the
selected
Phone Book Group
.
The dialer will contact the above 2 phone numbers at specific points of
time while the test is running.
Volume
button adjusts the volume level.
Threshold Settings
button opens a new page that allows you to set the
POTS Auto Test
threshold parameters.
Mute/Unmute Speaker
button changes the speaker status.
Result
displays the number dialed and its status, measurement values
of the multiple test parameters and their pass/fail status.
Test Status
displays the current state of measurement or an error
message.
To select the parameter values:
1.
Press the up/down arrow keys to highlight the desired parameter.
2.
Press the left/right arrow keys to view and select the options.
OR
3.
Press
on a value to open a list box of options.
4.
Press
to confirm the value.