Maintenance
B
A
C
D
E
F
g027660
Figure 38
7. Check the oil level; refer to
Checking the
Engine Oil Level–Exmark 708cc Engine
section.
8. Start the engine and check for leaks.
Changing the Engine Oil-Kohler
Engine
Service Interval: After the first 5 hours
Every 100 hours (change
it more often under a
heavy load or in high
temperatures) (Kohler
Engine).
1. Park the machine so that the drain side is slightly
lower than the opposite side to ensure the oil
drains completely.
2. Start the engine and let it run until warm. This
warms the oil so it drains better.
3. Disengage the blade control switch and ensure
the parking brake is engaged.
4. Stop the engine, remove the key, and wait for all
moving parts to stop before leaving the operating
position.
Figure 39
Note:
Torque the plug to 14 N-m (125 in-lb).