Figure 5
Front left anti-scalp bracket shown
1.
Type 1 hardware
2.
Type 2 hardware
3.
Type 3 hardware
4.
Type 4 hardware
5.
(Type 1) 3/8–16 x 4 hex screw
6.
(Type 2 & 3) 3/8–24 x 2 hex screw — Torque to 50–55 ft-lb
(68–75 N-m)
7.
(Type 4) 3/8 whizlock nut — Torque to 30–35 ft-lb
(41– 47 N-m)
8.
Spring disc washer (cone towards bolt head)
9.
(Type 1) 3/8 whizlock nut and heavy flat washer — Torque
to 40–45 ft-lb (54–61 N-m)
10.
(Type 2) 3/8 nyloc nut and heavy flat washer — Torque to
30–35 ft-lb (41–47 N-m)
11.
(Type 3) 3/8 flanged nyloc nut without washer — Torque
to 30–35 ft-lb (41– 47 N-m)
12.
(Type 4) 3/8 nyloc nut —Torque to 30–35 ft-lb (41– 47 N-m).
Servicing the Battery
WARNING
CALIFORNIA
Proposition 65 Warning
Battery posts, terminals, and related
accessories contain lead and lead compounds,
chemicals known to the State of California
to cause cancer and reproductive harm.
Wash hands after handling.
Important:
The machine is shipped with a filled
lead acid battery.
1. Remove the battery cover from machine.
DANGER
Charging the battery may produce explosive
gasses. Battery gasses can explode causing
serious injury.
•
Keep sparks, flames, or cigarettes away from
battery.
•
Ventilate when charging or using battery in
an enclosed space.
•
Make sure venting path of battery is always
open once battery is filled with acid.
2. Check the voltage of the battery with a digital
voltmeter. Locate the voltage reading of the battery
in the table below and charge the battery for the
recommended time interval to bring the charge up
to a full charge of 12.6 volts or greater.
Important:
Make sure the negative battery
cables are disconnected and the battery charger
used for charging the battery has an output of
16 volts and 7 amps or less to avoid damaging
the battery (see chart below for recommended
charger settings).
Voltage
Reading
Percent
Charge
Maximum
Charger
Settings
Charging
Interval
12.6 or
greater
100%
16 volts/7
amps
No Charging
Required
12.4 – 12.6
75–100%
16 volts/7
amps
30 Minutes
12.2 – 12.4
50–75%
16 volts/7
amps
1 Hour
12.0–12.2
25–50%
14.4 volts/4
amps
2 Hours
11.7–12.0
0–25%
14.4 volts/4
amps
3 Hours
11.7 or less
0%
14.4 volts/2
amps
6 Hours or
More
4