background image

BACKUP

 

RELIEF

 

BELT

 

USER

 

MANUAL

 

 

Ver.

 

1.0

 

Unikia

 

AS

 

Sandakerveien

 

24c,

 

Bygg

 

c1,

 

0473

 

Oslo,

 

Norway

                                             

2

 

 

specifically

 

target

 

back

 

pain.

   

This

 

innovative

 

device

 

is

 

safe,

 

drug

free,

 

easy

 

to

 

use,

 

discreet

 

and

 

comfortable

 

to

 

wear,

 

and

 

most

 

importantly

 

allows

 

you

 

to

 

control

 

your

 

pain

 

to

 

maintain

 

an

 

active

 

lifestyle.

 

3

 

Before

 

use

 

Your

 

Backup

 

Belt

 

has

 

been

 

designed

 

with

 

the

 

home

 

user

 

in

 

mind.

 

Please

 

consult

 

the

 

safety

 

precautions

 

and

 

contraindications

 

in

 

this

 

manual

 

prior

 

to

 

use.

 

Before

 

using

 

the

 

main

 

unit

 

the

 

first

 

time

 

please

 

charge

 

the

 

main

 

unit.

 

Insert

 

the

 

usb

 

cable

 

to

 

the

 

charger.

 

Plug

 

the

 

charger

 

into

 

the

 

mains

 

making

 

sure

 

before

 

that

 

the

 

charger

 

is

 

compatible

 

to

 

the

 

mains

 

in

 

your

 

current

 

location.

 

Then

 

connect

 

the

 

main

 

unit.

 

The

 

main

 

unit

 

indicator

 

light

 

will

 

flash

 

green

 

every

 

5th

 

second

 

during

 

charging.

 

The

 

unit

 

is

 

fully

 

charged

 

after

 

2

 

hrs

 

(2000

 

mAh).

 

 

4

 

Support

 

functionality

 

The

 

support

 

function

 

of

 

your

 

Backup

 

Belt

 

is

 

completely

 

analog

 

and

 

ready

 

to

 

use.

 

Put

 

on

 

the

 

belt

 

like

 

this:

 

1.

 

1.Make

 

sure

 

the

 

belt

 

is

 

facing

 

the

 

right

 

way.

 

The

 

magnetic

 

connectors

 

should

 

face

 

towards

 

your

 

body

 

and

 

down

 

2.

 

The

 

belt

 

length

 

can

 

be

 

adjusted

 

by

 

moving

 

the

 

inner

 

right

 

&

 

left

 

belt

 

along

 

the

 

belt

 

backplate,

 

fastening

 

by

 

means

 

of

 

the

 

velcro.

 

3.

 

To

 

insert

 

the

 

main

 

unit

 

insert

 

the

 

notch

 

in

 

the

 

top

 

of

 

the

 

main

 

unit

 

into

 

the

 

matching

 

tab

 

on

 

the

 

belt

 

backplate.

 

Then

 

press

 

main

 

unit

 

through

 

the

 

opening

 

allowing

 

the

 

magnetic

 

connectors

 

on

 

the

 

main

 

unit

 

&

 

belt

 

backplate

 

to

 

connect.

   

Summary of Contents for 002

Page 1: ...kerveien 24c Bygg c1 0473 Oslo Norway Product Name BACKUP BELT Model Number 002 Company name EXPAIN AS Address Karl Johans gate 13 0154 Oslo Norway Contact Name Thomas Jakobsen Telephone number 47 970...

Page 2: ...rt functionality 2 5 TENS functionality 3 APPLYING THE GEL PADS TO THE MAIN UNIT 3 HOW DOES IT WORK 4 TREATMENT RECOMMENDATIONS 4 CONDUCTING A TENS TREATMENT 4 6 HEAT functionality 5 CONDUCTING A HEAT...

Page 3: ...ere the gel pads are placed b Electronics housing 4 USB cable Charger 5 Gel pads 6 Manual CONTROLS 7 Main unit On Off 8 Main unit Indicator Light 9 Remote unit On Off 10 TENS On button 11 TENS Off but...

Page 4: ...t the charger is compatible to the mains in your current location Then connect the main unit The main unit indicator light will flash green every 5th second during charging The unit is fully charged a...

Page 5: ...ng belts and pull them until you feel you have desired support Fasten with the Velcro Right hand side goes over the left hand side here too 5 TENS functionality Before using the TENS functionality of...

Page 6: ...e the protective liners from the skin side of the gel pads by slowly peeling the liner diagonally from an inside corner to the opposite outside corner Important Avoid contact of the gel pad with other...

Page 7: ...yellow for 10 seconds to indicate a heat treatment has started The heating temperature is 42 C It will take a bit of time before you can feel the heat after activation The unit will have enough batter...

Page 8: ...ot Note The is facing upward Reverse the process to close the remote 9 Maintenance and storage Clean the device using a damp cloth and mild soap Gently wipe clean The right left inner belts can be was...

Page 9: ...rk activities SAFETY CONTRAINDICATIONS Do not use the TENS treatment on this device if you have a cardiac pacemaker implanted defibrillator or other implanted metallic or electronic device Such use co...

Page 10: ...Do not use the device s TENS treatment over or in proximity to these skin conditions abnormal skin skin that is not intact uncleaned unhealthy open wounds rashes swollen red infected inflamed areas sk...

Page 11: ...2 Not applicable Voltage fluctuations flicker emissions IEC 61000 3 3 Not applicable GUIDANCE AND MANUFACTURER S DECLARATION ELECTROMAGNETIC IMMUNITY The Backup Belt is intended for use in the electr...

Page 12: ...fied below The customer or the user of the Backup Belt should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Con...

Page 13: ...relocating the Backup Belt Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m RECOMMENDED SEPARATION DISTANCES BETWEEN PORTABLE AND MOBILE RF COMMUNICATIONS EQUIPMEN...

Page 14: ...ncy energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a...

Reviews: