1.

 

Trim,

 

not

 

shave,

 

excessive

 

hair

 

on

 

the

 

treatment

 

area.

 

2.

 

Wash

 

the

 

skin

 

and

 

dry

 

completely

 

3.

 

Separate

 

the

 

two

 

gel

 

pads.

 

4.

 

Remove

 

the

 

film

 

with

 

print

 

reading

 

“ELECTRODE”

 

from

 

the

 

side

 

being

 

applied

 

to

 

the

 

electrode

 

area.

 

This

 

film

 

is

 

the

 

smallest

 

of

 

the

 

two.

 

Do

 

not

 

remove

 

the

 

protective

 

liner

 

on

 

the

 

“skin

 

side”

 

yet.

 

5.

 

Align

 

the

 

shape

 

of

 

the

 

first

 

gel

 

pad

 

with

 

the

 

electrode

 

area.

 

Apply

 

the

 

gel

 

pad

 

onto

 

the

 

electrode

 

area

 

and

 

firmly

 

press

 

across

 

the

 

entire

 

surface

 

to

 

ensure

 

good

 

adhesion.

 

6.

 

Repeat

 

steps

 

3

 

 

5

 

for

 

the

 

second

 

gel

 

pad.

 

 

HOW DOES IT WORK 

Tens

 

treatment

 

works

 

in

 

two

 

ways.

 

It

 

stimulates

 

nerves

 

that

 

normally

 

carries

 

pain

 

signals

 

thus

 

“blocking”

 

these

 

(“closing

 

the

 

pain

 

gate”).

 

It

 

also

 

releases

 

endorphins

 

as

 

if

 

from

 

exercise,

 

endorphins

 

is

 

the

 

body`s

 

“natural

 

pain

 

killers”.

 

TREATMENT RECOMMENDATIONS 

 

You

 

can

 

leave

 

the

 

device

 

in

 

position

 

for

 

multiple

 

treatments

 

during

 

the

 

day.

 

It

 

will

 

automatically

 

turn

 

Off

 

after

 

one

 

(1)

 

hour

 

of

 

treatment.

 

If

 

no

 

treatment

 

is

 

active

 

the

 

unit

 

will

 

turn

 

off

 

completely

 

after

 

15

 

minutes.

 

 

It

 

is

 

recommended

 

you

 

wait

 

a

 

minimum

 

of

 

30

 

minutes

 

between

 

treatments.

 

CONDUCTING A TENS TREATMENT 

Always

 

read

 

the

 

safety

 

warnings

 

before

 

conducting

 

a

 

treatment.

 

Follow

 

these

 

steps

 

to

 

conduct

 

a

 

treatment:

 

1.

 

Remove

 

the

 

protective

 

liners

 

from

 

the

 

“skin

 

side”

 

of

 

the

 

gel

 

pads

 

by

 

slowly

 

peeling

 

the

 

liner

 

diagonally

 

from

 

an

 

inside

 

corner

 

to

 

the

 

opposite

 

outside

 

corner.

   

Important!

 

Avoid

 

contact

 

of

 

the

 

gel

 

pad

 

with

 

other

 

objects.

 

Contact

 

with

 

other

 

objects

 

may

 

affect

 

the

 

pads

 

adhesion

 

properties.

 

Save

 

the

 

liners

 

for

 

storage

 

of

 

the

 

device.

 

2.

 

Align

 

the

 

center

 

of

 

the

 

device

 

over

 

the

 

spine

 

and

 

place

 

the

 

device

 

on

 

your

 

back

 

in

 

the

 

area

 

of

 

pain.

 

If

 

you

 

cannot

 

place

 

the

 

device

 

properly,

 

ask

 

another

 

person

 

for

 

assistance.

 

Important!

 

Do

 

not

 

apply

 

the

 

gel

 

pads/electrodes

 

directly

 

over

 

the

 

spine.

 

3.

 

Press

 

the

 

On/Off

 

button

 

on

 

the

 

main

 

unit.

 

The

 

LED

 

will

 

flash

 

green

 

for

 

10

 

seconds

 

indicating

 

the

 

device

 

is

 

ready

 

for

 

use.

 

4.

 

Press

 

the

 

ON/OFF

 

button

 

on

 

the

 

remote.

 

Both

 

signal

 

lights

 

will

 

blink

 

twice

 

to

 

signal

 

remote

 

is

 

on.

 

Then

 

press

 

the

 

“+”

 

button

 

on

 

the

 

remote

 

control

 

to

 

begin

 

the

 

treatment.

 

The

 

TENS

 

signal

 

light

 

on

 

the

 

remote

 

will

 

blink

 

once

 

to

 

indicate

 

signal

 

is

 

sent

 

from

 

remote.

 

Note:

 

The

 

LED

 

on

 

the

 

main

 

unit

 

will

 

flash

 

blue

 

for

 

10

 

seconds

 

to

 

indicate

 

TENS

 

treatment

 

is

 

activated.

 

5.

 

Press

 

the

 

(+/

)

 

buttons

 

to

 

increase

 

or

 

decrease

 

the

 

intensity

 

of

 

the

 

stimulation

 

until

 

it

 

is

 

at

 

a

 

comfortable

 

level.

 

There

 

are

 

4

 

levels.

 

6.

 

Press

 

the

 

ON/OFF

 

button

 

on

 

the

 

remote

 

control

 

to

 

stop

 

the

 

treatment

 

at

 

any

 

time.

 

Both

 

indicator

 

lights

 

will

 

blink

 

twice

 

to

 

signal

 

remote

 

is

 

off.

 

Treatment

 

will

 

automatically

 

stop

 

after

 

1

 

hour

 

of

 

inactivity

 

(not

 

pressing

 

any

 

buttons)

 ‐ 

Alternatively

 

press

 

the

 

 

button

 

several

 

times

 

to

 

reduce

 

intensity

 

and

 

finally

 

turn

 

off

 

the

 

treatment.

   

Summary of Contents for 002

Page 1: ...kerveien 24c Bygg c1 0473 Oslo Norway Product Name BACKUP BELT Model Number 002 Company name EXPAIN AS Address Karl Johans gate 13 0154 Oslo Norway Contact Name Thomas Jakobsen Telephone number 47 970...

Page 2: ...rt functionality 2 5 TENS functionality 3 APPLYING THE GEL PADS TO THE MAIN UNIT 3 HOW DOES IT WORK 4 TREATMENT RECOMMENDATIONS 4 CONDUCTING A TENS TREATMENT 4 6 HEAT functionality 5 CONDUCTING A HEAT...

Page 3: ...ere the gel pads are placed b Electronics housing 4 USB cable Charger 5 Gel pads 6 Manual CONTROLS 7 Main unit On Off 8 Main unit Indicator Light 9 Remote unit On Off 10 TENS On button 11 TENS Off but...

Page 4: ...t the charger is compatible to the mains in your current location Then connect the main unit The main unit indicator light will flash green every 5th second during charging The unit is fully charged a...

Page 5: ...ng belts and pull them until you feel you have desired support Fasten with the Velcro Right hand side goes over the left hand side here too 5 TENS functionality Before using the TENS functionality of...

Page 6: ...e the protective liners from the skin side of the gel pads by slowly peeling the liner diagonally from an inside corner to the opposite outside corner Important Avoid contact of the gel pad with other...

Page 7: ...yellow for 10 seconds to indicate a heat treatment has started The heating temperature is 42 C It will take a bit of time before you can feel the heat after activation The unit will have enough batter...

Page 8: ...ot Note The is facing upward Reverse the process to close the remote 9 Maintenance and storage Clean the device using a damp cloth and mild soap Gently wipe clean The right left inner belts can be was...

Page 9: ...rk activities SAFETY CONTRAINDICATIONS Do not use the TENS treatment on this device if you have a cardiac pacemaker implanted defibrillator or other implanted metallic or electronic device Such use co...

Page 10: ...Do not use the device s TENS treatment over or in proximity to these skin conditions abnormal skin skin that is not intact uncleaned unhealthy open wounds rashes swollen red infected inflamed areas sk...

Page 11: ...2 Not applicable Voltage fluctuations flicker emissions IEC 61000 3 3 Not applicable GUIDANCE AND MANUFACTURER S DECLARATION ELECTROMAGNETIC IMMUNITY The Backup Belt is intended for use in the electr...

Page 12: ...fied below The customer or the user of the Backup Belt should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Con...

Page 13: ...relocating the Backup Belt Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m RECOMMENDED SEPARATION DISTANCES BETWEEN PORTABLE AND MOBILE RF COMMUNICATIONS EQUIPMEN...

Page 14: ...ncy energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a...

Reviews: