117
FC.06, the slip compensation will act.
F3.04
Motor rated frequency
1.00~550.00Hz
Model
determinati
F3.05
Motor rated voltage
1~480V
Model
determinati
F3.06
No-load current I0
0.1~999.9A
Model
determinati
F3.07
Stator resistance R1
0.000~50.000Ω
Model
determinati
F3.08
Leakage inductance X
0.0~999.9mH
Model
determinati
F3.09
Rotor resistance R2
0.000~50.000Ω
Model
determinati
F3.10
Mutual inductance Xm
0.0~999.9mH
Model
determinati
on
The specific meanings of the above motor parameters are shown in Figure 6-15.
Figure 6-15 Steady-state Equivalent Circuit Diagram of Asynchronous Motor
In Figure 6-15, Rs, Lls, Rr, Llr, Lm and I0 respectively represent stator resistance,
stator leakage inductance, rotor resistance, rotor leakage inductance, mutual inductance
and no-load current.