EXPERT Standard Series User Manual
152
For analog output of AO1 and expansion card AO2, if the user needs to change the
display range or correct the meter error, this can be realized by adjusting the output gain.
F6.29
Analog input voltage and
current type selection
000~111
000
Figure 6-35 Analog Output Type Settings
Note: This function code affects the analog output in real time during modification.
F6.30
Normal IO filter time
0.000~10.000s
0.008s
Input filter of DI1~DI10 normal terminal functions
F6.32
Expansion card DI10 input
function selection
Same as function code
F6.00
0
F6.33
Expansion card DO3
output function selection
Same as function code
F6.11
0
F6.34
Expansion card relay
output RA/RB/RC
Same as function code
F6.13
0
F6.35
AO1 zero offset coefficient
0.0%~100.0%
0.0%
F6.36
DO pulse duty cycle
0~100
50
F6.37
AO2 zero offset coefficient
0.0%~100.0%
0.0%
The calculation formula of AO high-precision analog output is shown in the following:
AO output = set value output * output gain - zero offset coefficient.