EXPERT Standard Series User Manual
157
6.9 Group F8 PID control parameters
The commonly used closed-loop control systems can be divided into two types of
analog closed-loop and pulse closed-loop according to different feedback quantities. Figure
6-36 and Figure 6-37 shown the wiring diagrams of analog closed-loop control and pulse
feedback closed-loop control composed of drives.
Figure 6-36 Schematic Diagram of Built-in PI Analog Feedback Control System
Figure 6-37 Wiring Diagram of PG Speed Closed-loop Control System
Using the pressure transmitter as the feedback sensor of the built-in PI can constitute