EXPERT Standard Series User Manual
163
When analog feedback is adopted (F8.02 = 0~5), this function realizes the digital
setting of the given quantity of the operation panel or serial port.
F8.06
Speed closed-loop given
0~39000rpm
0rpm
When PG pulse feedback is used (F8.02=6), set the given value of speed using the
operation panel or serial port communication.
F8.07
PPR of pulse encoder
1~20000
1024
Determined by the characteristic parameters of pulse encoder.
F8.08
Minimum given quantity
0.0%~F8.10
0.0%
F8.09
Feedback quantity
corresponding to minimum
given quantity
0.0~100.0%
0.0%
F8.10
Maximum given quantity
F8.08~100.0%
100%
F8.11
Feedback quantity
corresponding to maximum
given quantity
0.0~100.0%
100%
F8.08~F8.11 define the relationship curves for the analog closed-loop given and the
expected feedback quantities. The set value is the percentage of the actual value of the
given quantity and feedback physical quantity relative to the reference value (10V or
20mA).
Feedback positive regulation
Figure 6-41 Given and Feedback Curves Schematic Diagram 1