EXPERT Standard Series User Manual
52
Parameter
code
Parameter
name
Setting range
Mini
munit
Default
value
Mod
ition
F2.02
Start frequency
duration
0.0~10.0s
0.1s
0.0s
○
F2.03
Start DC braking
current
0.0~100.0% drive rated currency
0.1%
80.0%
○
F2.04
Start DC braking
time
0.0 (no action)
0.1~30.0s
0.1s
0.0s
○
F2.05
Acceleration and
deceleration mode
selection
0:Straight line acceleration and
deceleration
1:Reserved
1
0
×
F2.06
Reserved
○
F2.07
Reserved
○
F2.08
Stop mode
0:Decelerate to stop
1:Coast to stop
2:Stop decele DC braking
3:Positioning deceleration stop
4: Decelerate to stop (overpressure
stall invalid)
1
0
×
F2.09
Stop DC braking
start frequency
0.00~60.00Hz
0.01Hz 0.00Hz
○
F2.10
Stop DC braking
waiting time
0.00~10.00s
0.01s
0.00s
○
F2.11
Stop DC braking
current
0.0~100.0% drive rated current
0.1%
80.0%
○
F2.12
Stop DC braking time 0.0 (no action)
0.1~60.0s
0.1s
0.0s
○
F2.13
Deceleration multiple 1.0~109.0
1
5.0
*
F2.14
Acceleration time 2
0.01~600.00
Note:default unit second; refer to
FC.09 for units of acceleration and
deceleration time selection
0.1
Model
determin
ed
○
F2.15
Deceleration time 2
0.1
○
F2.16
Acceleration time 3
0.1
○
F2.17
Deceleration time 3
0.1
○
F2.18
Acceleration time 4
0.1
○
F2.19
Deceleration time 4
0.1
○