EXPERT Standard Series User Manual
59
Parameter
code
Parameter
name
Setting range
Mini
munit
Default
value
Mod
ition
F6.11
Open collector
output terminal DO1
0:Drive running indication (RUN)
1:Frequency arrival signal (FAR)
2:Frequency level detection signal
(FDT1)
3:Frequency level detection signal
(FDT2)
4:Overload detection signal (OL)
5:Stop for undervoltage block (LU)
6:External fault halt (EXT)
7:Frequency upper limit (FHL)
8:Frequency lower limit (FLL)
9:Drive zero-speed running
10:Simple PLC stage running
completion instruction
11:PLC circulation completion
indication
12:Reach setting count value
13:Reach specified count value
14:Setting length arrival indication
15:Drive running preparation
completed (RDY)
16:Drive fault
17:Upper computer switching signal
18:Reserved
19:Reach setting accumulated
running time
20:Output frequency (0~F1.06
maximum)
21:Reserved
22:Setting frequency (0~F1.06
maximum)
23:Output current(0~2*drive rated
current)
24:Output current(0~2*Motor rated
current )
25:Output torque(0~2*Tem)
1
0
×
F6.12
Open collector
output terminal DO2
1
1
×