EXPERT Standard Series User Manual
67
Parameter
code
Parameter
name
Setting range
Mini
munit
Default
value
Mod
ition
F9.07
Multistage frequency
7
F1.10(lower limit frequency)~
F1.09(upper limit frequency)
0.01Hz 50.00Hz
○
F9.08
Stage 1 setting
LED units digit:
0:Multistage frequency 1(F9.01)
1:Determined by F1.02 function
code
2:Multistage closed loop given
1(F8.20)
3:Determined by F8.01 function
code
LED tens digit:
0:Foreward
1:Reversal
2:Determined by run command
LED hundreds digit:
0:Acceleration and deceleration
time 1
1:Acceleration and deceleration
time 2
2:Acceleration and deceleration
time 3
3:Acceleration and deceleration
time 4
1
000
○
F9.09
Stage 1 running time 0.0~6500.0s
0.1
20.0
○
F9.10
Stage 2 setting
LED units digit:
0:Multistage frequency 2(F9.02)
1:Determined by F1.02 function
code
2:Multistage closed loop given
2(F8.21)
3:Determined by F8.01 function
code
LED tens digit:
0:Foreward
1:Reversal
2:Determined by run command
LED hundreds digit:
0:Acceleration and deceleration
time 1
1:Acceleration and deceleration
time 2
2:Acceleration and deceleration
time 3
3:Acceleration and deceleration
time 4
1
000
○