Parameter
code
Parameter
name
Setting range
Mini
munit
Default
value
Mod
ition
FC.02
AVR function
0:No action
1:Action all the time
2:No action only in deceleration
1
2
×
FC.03
Automatic energy
saving running
0:No action
1:Action
1
0
○
FC.04
Slip compensation
gain
0.0%~200%
1
0
○
FC.05
Slip compensation
limit threshold
0.0%~250%
FC.06
Slip compensation
filtering time
0.1~25.0ms
0.1ms 1.0ms
○
FC.07
Reserved
FC.08
Cooling fan control
0:Automatic running
Note:Run for 3 minutes after stop
1:Fan always running when power on
2:Fan starts running when operating
temperature is above 45℃,stops when
temperature is below 40℃
1
0
×
FC.09
Acceleration and
deceleration time
unit
0:(second)
1:(minute)
0
0
×
FC.10
Droop control
0.00~10.00Hz
0.01Hz 0.00Hz
○
FC.11
Acceleration and
deceleration time
filter coefficient
0.1~100.0
0.1
1.0
○
FC.12
Zero frequency
running threshold
value
0.00~550.00Hz
0.01Hz 0.00Hz
○
FC.13
Zero frequency
return difference
0.00~550.00Hz
0.01Hz 0.00Hz
○
FC.14
Length setting
0.00~65.535km
0.001 0.000
○
FC.15
Actual length
0.00~65.535km
0.001 0.000
○
FC.16
Length multiplying
power
0.001~30.000
0.001 1.000
○
FC.17
Length correction
coefficient
0.001~1.000
0.001 1.000
○
FC.18
Measurement axis
perimeter
0.01~100.00(cm)
0.01
(cm)
10.00(c
m)
○
FC.19
Axis pulse per turn
1~9999
1
1
○