EXPERT Standard Series User Manual
82
Parameter
code
Parameter
name
Setting range
Mini
munit
Default
value
Mod
ition
FC.31
Keypad function and
lock selection
LED units digit:
key function
selection
0:Ineffective in non-panel control
mode
1:Stop according to stop mode in
non-panel mode
2:E015 free halt in non-panel
mode
LED tens digit:reserved
LED hundreds digit:Keyboard lock
function
0:No lock
1:All lock
2:All lock except for
key
3:All lock except for ENT key
4:All lock except for RUN and
key
1
000
×
FC.32
Reserved
-
-
0
*
FC.33
Frequency source
overlay selection
Digit:Frequency source selection
0:The main frequency source
1:Primary and secondary operation
results (the results are determined by
the tens digit)
2:The main frequency source
switching with the auxiliary frequency
source
3:The main frequency source
switching with Primary and secondary
operation results