36
Note:
If a new cylinder has just been connected, please allow at least one minute for the
air in the gas pipeline to purge out through the pilot hole.
When lighting the pilot flame, make sure that the variable control knob is
continously pressed down while pressing the igniter button. The variable control
knob can be released after the pilot flame lights.
Pilot flame can be watched and checked from the small round window with
sliding lid located at the bottom of the flame screen (to the left or right side of the
controller).
If the pilot flame does not light or it goes out, repeat step 3.
4. After the pilot flame lights, turn the variable control knob to maximum position
and leave it there for 5 minutes or more before turning the variable control knob
to the desired temperature position.
To turn off the heater.
Abschalten des Heizers
1. Turn the variable control knob to PILOT position.
2. Press and turn the variable control knob to OFF position.
3. Turn off the valve on the gas supply cylinder completely.
Storage
1. Always close the gas valve of the gas cylinder after use or in case of distur-
bance.
2. Remove the pressure controller and the hose.
3. Check the tightness of the gas valve and for damage. If you suspect a damage,
have it changed by your gas dealer.
4. Never store liquid gas cylinders in a sub-terrain, or at places without adequate
air ventilation.