CARAT
19
As an additional safety, all dose settings have a maximum dispensing time of 5 minutes.
Maximum security time
PROGRAMMING
Clock adjustment, hour, minutes and day
To adjust the clock press the button
(2 short espresso) while “Clock
adjust” is displayed.(See fig. C)
The hour starts to flash, increase or decrease its value by pressing the button
(1 short espresso) or
(1 long espresso).
When the rightvalue is reached, accept it by pressing the button
(2 short espresso).
Now the minutes starts to flash, increase or decrease its value by pressing
the button
(1 short espresso) or
(1 long espresso).
When the right value is reached, accept it by pressing the button
(2 short espresso). Then the day of the week can be adjusted in
the same way (
,
&
).
When all values have been adjusted and is confirmed with button
(2 short espresso) the display will proceed to the next menu.
Clock Adjust
HH:MM Day
1 short espresso
↑ +
1 long espresso
↓
-
2 short espresso OK
Continuous to confirm
fig.C
Access to second level menus
Keep the continuous button
pressed over 8 seconds on the left
keypad.
(Entering first level, See fig. A). Now all the lights in the keypad will light up
and continuous button will flash. Do not release the continuous button
until the display shows “Clock adjust”(See fig. B). From this point we
are in the second level menu.
Enter “Clock adjust” by pressing the button
(2 short espresso) or
browse through the system with button
(1 short espresso) or
(1 long espresso).
Doses Programming
Select 30s
Clock Adjust
1 short espresso
↑ +
1 long espresso
↓
-
2 short espresso OK
Continuous to confirm
fig.A
fig.B
Summary of Contents for CARAT 1GR
Page 1: ...CARAT TECHNICAL MANUAL TM_EN Part No 1764016_01 Date 150413 ...
Page 40: ...CARAT 40 WATER SYSTEM Machine with 1GR Cold water Hot water Drain waste water ...
Page 41: ...CARAT 41 WATER SYSTEM Machine with 2GR Cold water Hot water Drain waste water ...
Page 46: ...CARAT 46 6 EXPLODEDVIEW Rotary pump Drawing 2 3 9 7 8 4 1 5 10 11 ...
Page 48: ...CARAT 48 EXPLODEDVIEW Boiler 1GR Drawing 1 11 12 13 14 7 8 16 17 18 9 6 4 5 5 3 2 10 15 ...
Page 50: ...CARAT 50 EXPLODEDVIEW Boiler 2GR Drawing 13 15 14 14 16 11 3 4 6 7 5 8 9 10 12 1 2 17 18 12 ...
Page 59: ...CARAT 59 EXPLODEDVIEW Hot water outlet Drawing 1 2 3 4 5 6 7 11 12 8 9 10 ...
Page 61: ...CARAT 61 EXPLODEDVIEW Group head Drawing 1 7 15 14 13 2 8 3 9 4 16 11 5 12 6 10 ...
Page 63: ...CARAT 63 EXPLODEDVIEW Lower water system Drawing 6 7 8 9 10 11 12 3 4 2 13 5 1 ...