14
QUARTZ
CLASSIC
10ºC
1ºC
100ºC
K5
K1
K2
SERVICE PROGRAMMING
Adjusting the boiler operating temperature
The boiler operating temperature is adjustable from 110ºC and 128ºC. To
adjust the boiler temperature, proceed as follows:
Set the machine to STANDBY mode by pressing the K3 and K5
buttons simultaneously for one second.
Press the K3 and K4 buttons simultaneously. The keypad will start to
flash to display the operating temperature of the boiler.
To determine the operating temperature, you must add all
buttons flashes together as explained below:
K5 represents one hundred degrees (one flash = 100ºC)
K1 represents ten degrees (one flash = 10ºC)
K2 represents single degrees (one flash = 1ºC)
Example: One K5 flash+one K1 flash+six K2 flashes= 116ºC
Press the K4 button to decrease the boiler temperature, or press
the K3 button to increase it. One button press equals one degree.
Switch the machine OFF and ON once to store the changes before using the
machine again.
Note:
• The temperature displayed represents the boiler temperature, not the temperature of the drink.
• The recommended boiler temperature is between 118ºC to 122ºC. (Default is 118ºC.)
i
K6
K3
K4
Summary of Contents for Quartz Classic One Touch
Page 1: ...R TM_EN Part No 1764264_05 QUARTZ CLASSIC TECHNICAL MANUAL...
Page 30: ...30 QUARTZ CLASSIC Machine Drawing EXPLODEDVIEW 06 05 14 04 03 02 10 08 11 13 12 01 09 07...
Page 36: ...36 QUARTZ CLASSIC Manifold system Drawing EXPLODEDVIEW 01 10 10 11 12 13 11 03 04 05 06 07 02...
Page 46: ...46 QUARTZ CLASSIC Water tank Drawing 01 02 03 04 05 EXPLODEDVIEW 06...
Page 48: ...48 QUARTZ CLASSIC 01 02 07 06 02 05 04 03 08 Water tap Drawing 09 10 EXPLODEDVIEW 13 12 11...