background image

18

DEUTSCH

 
TOUR
 
DMX KANAL

 

WERT

 
FUNKTION

1

0

ó

255

MASTER DIMMER

2

0

ó

255

RED

3

0

ó

255

GREEN

4

0

ó

255

BLUE

5

0

ó

255

WHITE

6

0

ó

255

AMBER

7

0

ó

255

CYAN

8

0

ó

255

UV

9

MARCOS

0

ó

10

NO FUNCTION

11

ó

30

RED 100%GREEN UP / BLUE  0%

31

ó

50

RED DOWN / GREEN 100% / BLUE 0%

51

ó

70

RED 0% / GREEN 100% / BLUE UP

71

ó

90

 RED 0% / GREEN DOWN / BLUE 100%

91

ó

110

RED UP / GREEN 0% / BLUE 100%

111

ó

130

RED 100% / GREEN 0% / BLUE DOWN

131

ó

150

RED 100% / GREEN UP / BLUE UP

151

ó

170

RED DOWN / GREEN DOWN / BLUE 100%

171

ó

195

ALL LEDS AT FULL OUTPUT

196

ó

200

2700K

201

ó

205

3000K

206

ó

210

3200K

211

ó

215

3500K

216

ó

220

4000K

221

ó

225

4200K

226

ó

230

4500K

231

ó

235

5600K

236

ó

240

6000K

241

ó

245

6500K

246

ó

250

7200K

251

ó

255

8000K

10

SPECIAL STROBE

0

ó

9

NO FUNCTION

10

ó

99

STROBE FROM SLOW TO FAST 0 - 25Hz

100

ó

109

NO FUNCTION

110

ó

179

LIGHTNING STROBE 

180

ó

189

NO FUNCTION

190

ó

255

RANDOM SROBE

Summary of Contents for AKKULED MINI ZOOM

Page 1: ...01 DEUTSCH AKKULED MINI ZOOM BEDIENUNGSANLEITUNG F R LED22630 USER MANUAL FOR LED22630 AKKULED MINI ZOOM...

Page 2: ...CHAFTEN TECHNISCHE DATEN Spannung 18 5 V DC Leistungsaufnahme 20 Watt Betriebstemperatur 0 40 C Schutzklasse IP 65 Breite 143 mm Tiefe 105 mm H he 190 mm Gewicht 1 00 kg 1 0 1 1 129 24 mm 104 37 mm 12...

Page 3: ...Es muss gew hrleistet werden dass das Ger t nicht verschmutzt ist ACHTUNG ERSTICKUNGSGEFAHR DURCH KUNSTSTOFFT TEN Das Produkt hat unser Werk in bestem Zustand verlassen Um diesen f r einen sicheren Be...

Page 4: ...ein SCHUTZARTEN ANHAND VON BEISPIELEN IP20 Fernhalten von Objekten 12 5mm Fingerschutz Kein Schutz gegen Wasser Typische Schutzklasse f r Ger te f r den Innenbereich IP33 Fernhalten von Fremdk rpern 2...

Page 5: ...Dichtungen Kabel und Oberfl chenbeschichtung f hren EINSCHR NKUNGEN DER IP SCHUTZART Eine IP Schutzart gibt nicht im allgemeinen eine Witterungsbe st ndigkeit an Faktoren wie Umgebungstemperatur und...

Page 6: ...blinkt STEHEND Das Ger t kann durch aufklappen des B gels sicher aufgestellt werden Diese Ger t ist ausschlie lich f r das Aufstellen auf sicheren Fl chen vorgesehen ACHTUNG HINWEIS Das LED Modul kan...

Page 7: ...en von Werten Up Scrollen durch das Men oder erh hen von Werten BEDIENUNG MEN STRUKTUR 3 2 3 1 STATICCOLOR ADRESS EDIT PERSONALITY AUTOPROGR MEN RED 001 512 PROGRAMM01 HSIC TOUR PROGRAMM02 PROGRAMM10...

Page 8: ...ERROR Im Men STATIC wird aus den Farbwerten sowie Zoom und Strobe anhand der DMX Werteskala 0 255 eine statische Szene einge stellt STATISCHE FARBE EINSTELLEN R 0 255 G 0 255 B 0 255 W 0 255 RGBtoW UC...

Page 9: ...inierte Programme PR01 PR10 siehe auch EDIT Im Men ADDRESS wird die DMX Startadresse des Ger tes einge stellt ABSPIELEN DER AUTOMATIK PROGRAMME DMX512 ADRESSE MEN MEN ADRESS 0 512 AUTOPROGR AUTO 01 P...

Page 10: ...rhalten gesteuert Es stehen verschiedene Halogensimu lationen zur Verf gung Im Men punkt DMX ERROR wird mit SAVE oder BLACK fest gelegt wie das Ger t sich bei St rung des DMX Signals verhalten soll PW...

Page 11: ...HER DIE REFRESHRATE EINGESTELLT WIRD DESTO GERINGER WIRD DIE GREYRATE FULL POWER CCT legt die Farbtemperatur fest 3200K 4200K 5600K NORMAL PASSWORTSCHUTZ 3 9 Im Men unter KEY wird eingestellt ob eine...

Page 12: ...NU unter CALIB C in die Korrektureinstellungen gehen Password UP DOWN UP DOWN ENTER Im CALIB C sind 12 vorprogrammierte Farbtemperaturen hinter legt Diese werden aus den Werte RED GREEN BLUE WHITE gem...

Page 13: ...KTE ABRUFEN EFFECTKEY 01 bis EFFECTKEY 06 dr cken um Effekte ab zu rufen Unter Editieren der Autoprgramme finden Sie weitere Infor mationen zur Programmierung der EFFECTKEY Tasten Mit SPEED und SPEED...

Page 14: ...gt werden Wenn die gr ne Status LED nicht leuchtet ist das Ger t nicht mit einem Sender verbunden Durch dr cken des RESET Knopfes am Sender sucht dieser nach Ger ten im Reset Mode Die gr ne Signal LED...

Page 15: ...50 60 Hz Leistungsaufnahme 150 Watt Breite 572 mm Tiefe 350 mm H he 240 mm Gewicht 9 80 kg Spannung AC 100 240 V 50 60 Hz Ausgang DC24V 1A LED 200 mA ACHTUNG HINWEIS LADEN Nicht l nger als 24 Stunden...

Page 16: ...00K 51 70 3200K 71 90 3500K 91 110 4000K 111 130 4200K 131 150 4500K 151 170 5600K 171 190 6000K 191 210 6500K 211 230 7200K 231 255 8000K 6 STROBE 0 9 NO FUNCTION 10 99 STROBE FROM SLOW TO FAST 0 25H...

Page 17: ...5 0 255 WHITE 6 0 255 AMBER 7 0 255 CYAN 8 0 255 UV 9 SPECIAL STROBE 0 9 NO FUNCTION 10 50 STROBE FROM SLOW TO FAST 0 25Hz 51 100 NO FUNCTION 101 150 LIGHTNING STROBE 151 200 NO FUNCTION 201 255 RAND...

Page 18: ...100 91 110 RED UP GREEN 0 BLUE 100 111 130 RED 100 GREEN 0 BLUE DOWN 131 150 RED 100 GREEN UP BLUE UP 151 170 RED DOWN GREEN DOWN BLUE 100 171 195 ALL LEDS AT FULL OUTPUT 196 200 2700K 201 205 3000K...

Page 19: ...130 ATUO9 131 140 ATUO10 141 150 PROGRAM1 151 160 PROGRAM2 161 170 PROGRAM3 171 180 PROGRAM4 181 190 PROGRAM5 191 200 PROGRAM6 201 210 PROGRAM7 211 220 PROGRAM8 221 230 PROGRAM9 231 255 PROGRAM10 12 0...

Page 20: ...16 MARCOS 0 10 NO FUNCTION 11 30 RED 100 GREEN UP BLUE 0 31 50 RED DOWN GREEN 100 BLUE 0 51 70 RED 0 GREEN 100 BLUE UP 71 90 RED 0 GREEN DOWN BLUE 100 91 110 RED UP GREEN 0 BLUE 100 111 130 RED 100 GR...

Page 21: ...50 ATUO1 51 60 ATUO2 61 70 ATUO3 71 80 ATUO4 81 90 ATUO5 91 100 ATUO6 101 110 ATUO7 111 120 ATUO8 121 130 ATUO9 131 140 ATUO10 141 150 PROGRAM1 151 160 PROGRAM2 161 170 PROGRAM3 171 180 PROGRAM4 181...

Page 22: ...S TECHNICAL SPECIFICATION voltage 18 5 V DC power consumption 20 Watt operation temperature 0 40 C protection class IP 65 width 143 mm depth 105 mm height 190 mm weight 1 00 kg 1 0 1 1 129 24 mm 104 3...

Page 23: ...0 5 m must be maintained between the equipment and a combustible surface The product must always be operated in a well ventilated area DO NOT stare directly into the LED light source Always disconnec...

Page 24: ...SE FIXTURES IP33 Protection against intruding objects 2 5mm Falling water within an angle of 60 has no harmful effect TYPICAL PROTECTION OF LED LIGHTS USING RECESSED POW ERCON AND DMX SOCKET This prot...

Page 25: ...longterm UV emission as sunlight and should be checked frequently LIMITATIONS OF IP PROTECTION IP Rating doesn t mean unlimited outdoor use and protection against any kind of enviromental influence E...

Page 26: ...fixture green light is always on When it s under infrared mode and there is infrared signal red light is flickering UPRIGHT The fixture can be mounted in an upright or sitting position using the suppo...

Page 27: ...down DISPLAY OPERATION MENU MAP 3 2 3 1 STATICCOLOR ADRESS EDIT PERSONALITY AUTOPROGR MENU RED 001 512 PROGRAMM01 HSIC TOUR PROGRAMM02 PROGRAMM10 SSP TR16 AUTO 01 0 255 0 255 0 255 SCENE01 SCENE02 SC...

Page 28: ...OR Create an infinite range of colors by using the DMXvalues for each single color 0 255 Set the value of the STROBE 0 25Hz for flash effect EDIT STATIC COLOUR R 0 255 G 0 255 B 0 255 W 0 255 RGBtoW U...

Page 29: ...n EDIT menu Programs PR 01 to PR 10 are fully pre programmed but can be edited in EDIT menu Enter the ADDRESS menu to set the DMX ADDRESS ACTIVATING AUTO PROGRAMS DMX512 SETTINGS MENU MENU ADRESS 0 51...

Page 30: ...s the creation of a scene using COLORS STROBE TIME FADE Sample for Time Settings by simple Stand Alone Programit with 3 Steps Step 1 Time 4 Use Yes Step 2 Time 5 Use Yes Step 3 Time 0 Use Yes EDITING...

Page 31: ...Select DIM1 DIM2 DIM3 or DIM4 for different dimming speeds DIM4 is the slowest DMX ERROR choose SAVE or BLACK in order to hold the last value or blackout the fixture when DMX signal is lost SPECIAL S...

Page 32: ...perature There are 12 pre programmed White colors can be edited by using the COLORS Enter the RGBW to adjust the RGB parameter to make different whites When the new setting is activated the DMX contro...

Page 33: ...as well as Flash frequency STROBE EFFECT CONTROLS Select EFFECTKEY 01 to EFFECTKEY 08 to play programmed Effects Select SPEED to adjust speed of effects It IS NOT POSSIBLE to adjust dimming of the ef...

Page 34: ...green signal indicator LED will not show which confirms that W DMX re ceiver card is unpaired and ready for new pairing By pressing the RESET button on W DMX transmitter transmitter will search for R...

Page 35: ...50 60 Hz rated power 150 Watt width 572 mm depth 350 mm height 240 mm weight 9 80 kg voltage AC 100 240 V 50 60 Hz output DC24V 1A LED 200 mA IMPORTANT FACTS CHARGING Do not charge for more than 24 ho...

Page 36: ...00K 51 70 3200K 71 90 3500K 91 110 4000K 111 130 4200K 131 150 4500K 151 170 5600K 171 190 6000K 191 210 6500K 211 230 7200K 231 255 8000K 6 STROBE 0 9 NO FUNCTION 10 99 STROBE FROM SLOW TO FAST 0 25H...

Page 37: ...E 5 0 255 WHITE 6 0 255 AMBER 7 0 255 CYAN 8 0 255 UV 9 SPECIAL STROBE 0 9 NO FUNCTION 10 50 STROBE FROM SLOW TO FAST 0 25Hz 51 100 NO FUNCTION 101 150 LIGHTNING STROBE 151 200 NO FUNCTION 201 255 RAN...

Page 38: ...UE 100 91 110 RED UP GREEN 0 BLUE 100 111 130 RED 100 GREEN 0 BLUE DOWN 131 150 RED 100 GREEN UP BLUE UP 151 170 RED DOWN GREEN DOWN BLUE 100 171 195 ALL LEDS AT FULL OUTPUT 196 200 2700K 201 205 3000...

Page 39: ...0 ATUO9 131 140 ATUO10 141 150 PROGRAM1 151 160 PROGRAM2 161 170 PROGRAM3 171 180 PROGRAM4 181 190 PROGRAM5 191 200 PROGRAM6 201 210 PROGRAM7 211 220 PROGRAM8 221 230 PROGRAM9 231 255 PROGRAM10 12 0 2...

Page 40: ...16 MARCOS 0 10 NO FUNCTION 11 30 RED 100 GREEN UP BLUE 0 31 50 RED DOWN GREEN 100 BLUE 0 51 70 RED 0 GREEN 100 BLUE UP 71 90 RED 0 GREEN DOWN BLUE 100 91 110 RED UP GREEN 0 BLUE 100 111 130 RED 100 G...

Page 41: ...1 50 ATUO1 51 60 ATUO2 61 70 ATUO3 71 80 ATUO4 81 90 ATUO5 91 100 ATUO6 101 110 ATUO7 111 120 ATUO8 121 130 ATUO9 131 140 ATUO10 141 150 PROGRAM1 151 160 PROGRAM2 161 170 PROGRAM3 171 180 PROGRAM4 181...

Page 42: ...WWW EXPOLITE LED DE...

Reviews: