MODELS • VCDD010

I

• VCDD015

I

VCDD020

I

• VCDD025

I

• VCDD030

I

Page 3

MOUNTING OPTIONS

DUCTING OPTIONS

DUCTING (Right-Angle Blower Discharge)

BLOWER DISCHARGE POSITIONS

Typical ductwork connection to a ventilator

converted to right-angle discharge.

* VCDD010

I

& VCDD015

I

use 6” round duct.

VCDD020

I

, VCDD025

I

& VCDD030

I

use 8” round duct.

USE AND CARE

Ventilator is designated for continuous operation. If desired, it
may be controlled using an on/off switch or a solid-state, 
variable speed control. Follow wiring instructions packed with
control, and adhere to all local and state codes, and the
National Electrical Code.

WARNING: To reduce the risk of electric shock,
disconnect from power supply before servicing.

To clean grille:

Use appropriate vacuum attachment or

remove grille and clean with a soft cloth and mild soap or 
detergent. Dry grille thoroughly before reinstalling.

To clean blower assembly:

Remove grille, unplug blower from

housing, remove blower mounting nuts, and carefully remove
blower from housing. Use appropriate vacuum attachment or a
soft cloth and mild soap detergent to clean blower discharge
area and wheel. NO NOT ALLOW WATER TO ENTER MOTOR.
Make sure blower assembly is completely dry before reinstalling.

Motor is permanently lubricated. Do not oil or disassemble motor.

Blower and duct connector 

in straight-through discharge

position. (Factory-shipped)

Blower and duct connector 

in right-angle discharge

position.

WIRING OPTIONS

Wiring plate mounts to side or top of housing.

WIRING PLATE 
POSITION

Mounting brackets in 

factory-shipped position. 

(Outlet parallel to joists.) 

(New construction)

Mounting brackets flipped

over and mounted to outlet

sides of housing. 

(Outlet parallel to joists.) 

(Existing construction)

Mounting brackets mounted 

to outlet sides of housing. 

(Outlet perpendicular to joists.) 

(New construction)

Mounting brackets flipped

over to give approx. 1” 

more clearance. 

(Outlet parallel to joists.) 

(New construction)

Mounting brackets mounted 

to top of sides of housing. 

(Outlet parallel to joists.) 

(New or existing construction)

Mounting brackets flipped

over and mounted to top 

sides of housing. 

(Outlet parallel to joists.) 

(New or existing construction)

¼-20 hex nuts secure mounting brackets to housing. Loosen
and re-tighten or remove and replace nuts as necessary for
desired mounting bracket position.

DUCT CONNECTOR

DUCT CONNECTOR

BLOWER

BLOWER

Change 

blower & 

duct connector  

positions for 

right angle
discharge.

ROOF CAP

ROUND

DUCT*

HORIZONTAL POWER

CABLE CONNECTION

VERTICAL

POWER

CABLE 

CONNECTION

Summary of Contents for VCDD0110I

Page 1: ...Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring or other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be installed over a tub or shower it must be marked as appropriate for the ap...

Page 2: ...twork Use duct tape to make ductwork connections secure and air tight Remove shipping ring from blower inlet Remove the shipping ring from the blower inlet before operating the ventilator WIRING Ventilator can be wired from outside of housing Use UL approved connectors to wire per local codes DUCTING Straight Through Blower Discharge ROUND DUCT ADDITIONAL 1 FRAMING MOUNTING SCREW Mounting brackets...

Page 3: ...e sure blower assembly is completely dry before reinstalling Motor is permanently lubricated Do not oil or disassemble motor Blower and duct connector in straight through discharge position Factory shipped Blower and duct connector in right angle discharge position WIRING OPTIONS Wiring plate mounts to side or top of housing WIRING PLATE POSITION Mounting brackets in factory shipped position Outle...

Page 4: ... 11 98009399 Inlet Ring 12 99110805 Blower Wheel 13 99080481 Motor VCDD010I 99080482 Motor VCDD015I 99080483 Motor VCDD020I 99080484 Motor VCDD025I 99080485 Motor VCDD030I 14 99260558 Lock Nut 8 32 4 req 15 99250959 Washer 4 req 16 99100491 Grommet 4 req Blower Assembly Complete Includes Key Nos 5 10 16 97014800 VCDD010I 97014801 VCDD015I 97014802 VCDD020I 97014803 VCDD025I 97014804 VCDD030I 17 99...