background image

MODELS

VCDD090

I

• VCDD150

I

Page 2

TYPICAL INSTALLATION

TYPICAL INSTALLATION

MOUNTING (New Frame Construction)

Factory-shipped unit installed in new construction.

MOUNTING (Existing Frame Construction)

Factory-shipped unit installed in existing construction.

Two ways to connect ductwork to a factory-shipped unit.

IMPORTANT:

Remove shipping tape from damper

Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork.
Use duct tape to make ductwork connections secure and air-tight.

WIRING

Ventilator can be wired from outside of housing.

Use UL approved connectors to wire per local codes.

DUCTING (Straight-Through Blower Discharge)

12” ROUND DUCT

(OUTLET)

8” X 12” TO 

12” ROUND

TRANSITIONS

MOUNTING
BRACKETS

CEILING 

JOIST

(24” centers 

shown)

Ventilator 

factory-shipped 

in straight-through 

discharge position.

CEILING 

JOIST

(24” 

centers 
shown)

FINISHED

CEILING

MATERIAL

MOUNTING 
BRACKETS

BLACK

TO

BLACK

WHITE

TO

WHITE

GROUND TO

WIRING PLATE

EDGE

OF HOUSING

WIRING

PLATE

120 VAC LINE IN

ROOF CAP

MOUNTING

SCREWS

GRILLE NUT

(Install into square 

holes in housing)

8” X 12” TO 12”

ROUND TRANSITIONS

Ventilator factory-shipped 

in straight-through 

discharge position.

GRILLE NUT

(Install into 

square holes in

housing)

12” ROUND 

DUCT

(INTAKE)

ACCESS

PANEL

SCREW

ACCESS PANEL

12” ROUND DUCT

(OUTLET)

ACCESS

PANEL SCREW

ACCESS 

PANEL

12” ROUND DUCT

(INTAKE)

12” 

ROUND 

DUCT

8” X 12” TO 

12” ROUND

TRANSITIONS

12” 

ROUND 

DUCT

12” 

ROUND 
ELBOW

WALL

CAP

Summary of Contents for VCDD0901

Page 1: ...tion and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring or other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be ...

Page 2: ...per local codes DUCTING Straight Through Blower Discharge 12 ROUND DUCT OUTLET 8 X 12 TO 12 ROUND TRANSITIONS MOUNTING BRACKETS CEILING JOIST 24 centers shown Ventilator factory shipped in straight through discharge position CEILING JOIST 24 centers shown FINISHED CEILING MATERIAL MOUNTING BRACKETS BLACK TO BLACK WHITE TO WHITE GROUND TO WIRING PLATE EDGE OF HOUSING WIRING PLATE 120 VAC LINE IN RO...

Page 3: ...traight through discharge position Factory shipped Ventilator shown in right angle discharge position Change movable panel to new location as shown WIRING OPTIONS Wiring plate mounts to side or top of housing WIRING PLATE POSITION Mounting brackets in factory shipped position mounted directly to joist Outlet parallel to joists New construction Mounting brackets flipped over and mounted to addition...

Page 4: ...iz Nut 20 11 req 17 99200202 Screw 20 x 5 req 18 97014785 Blower Scroll 19 99080490 Motor VCDD090I 99080491 Motor VCDD150I 20 93260447 Nut Hex Flange 5 16 18 5 req 21 98009516 Support Bracket 22 99680019 Wheel Clamp 23 99020274 Blower Wheel includes Key No 22 24 98009514 Inlet Ring 25 99150417 Screw 8 18 x 5 req 26 98009513 Scroll Support Channel 97014848 Blower Assembly Complete VCDD090I Includes...

Reviews: