26
ELECTRICAL CONNECTION
•
The installation of this appliance and the connection to the electrical system should be
entrusted only to a qualified electrician.
•
Protection against the parts under tension must be ensured after instalation
•
The data of connection necessary are on the stickers place on the hob casing near the
connection box.
•
The connection to the mains must be made using an earthed plug or via an omnipolar circuit
breaking device with a contact opening of at least 3 mm.
•
The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
•
If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
•
The inlet hose must be positioned so that it does not touch any of the hot parts of the hob or
even.
Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz
Always connect the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover, use a
medium screwdriver. Place it in the slits and open the cover.
( * ) calculated with the simultaneous factor following standard EN 60 335-2-6
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal.
Monophase 230V~1P+N
Put a bridge between terminal 1 and 2.
Attach the earth to the terminate “earth”, the neutral N to terminal 4, the Phase L to one of the
terminals 1 or 2.
Biphase 400V~2P+N
Attach the earth to the terminate “earth”, the neutral N to terminal 4, the Phase L1 to the terminals 1
and the Phase L2 to the terminal 2.
Caution!
Frequent loosening and screwing of the screws on the connection box risks
damaging the efficiency of the tightness once screwed. It is therefore advisable
to keep screwing and unscrewing to a minimum.
Ensure that the cables are correctly inserted and tightly screwed down.
We cannot be held responsible for any accident resulting from incorrect connection or which
could arise from the use of an appliance which has not been earthed or has been equipped
with a faulty earth connection
Mains
Connection
Cable diameter
Cable
Protection calibre
230V~ 50/60Hz
1 Phase + N
3 x 2,5 mm²
H 05 VV - F
H 05 RR - F
25 A *
400V~ 50/60Hz
2 N
4 x 2.5 mm²
H 05 VV - F
H 05 RR - F
16 A *