382100-EU-EN v2.2 07/13
5
2.0 Specifications
2.1 General Specifications
Circuit
Custom one-chip microprocessor LSI circuit
Display
LCD Size: 81.4 X 61 mm (3.2 X 2.4”)
Dot Matrix backlit LCD (320 X 240 pixels)
Measurements
ACV / ACA / AC Watts (True Power)
AC Watts (Apparent Power)
AC Watts (Reactive Power)
Power factor
Phase angle
Frequency
Wire connections
1P/2W, 1P/3W, 3P/3W, 3P/4W.
Voltage ranges
10 ACV to 600 ACV (Auto Range)
Current ranges
0.2 ACA to 1200 ACA (Auto / Manual Range)
Safety standard
IEC1010 CAT III 600 V
ACV input impedance
10M ohms
Range select
ACV
Auto Range
ACA
Auto / Manual Range
Clamp frequency
response
40 Hz to 1 KHz
Tested frequency
45 to 65 Hz
Over load protection
ACV
720 ACV RMS
ACA
1300 ACA with clamp probe
Over-range indicator
"OL"
Under-range indicator
"UR"
Data Hold
Freezes displayed reading
Data Recording
SD memory card
Sampling Time
Approx. 1 second
Datalogger
Real time data logger saves data to SD memory card for download to
PC (data file opens directly to spreadsheet)
Sampling rate: 2 seconds to 7200 seconds
Data Output
Serial or USB connection (cable supplied)
Operating Temp.
0 to 50
o
C (0 to 122
o
F)
Operating R.H.
80% Relative Humidity max.
Power Supply
Eight (8) ‘AA’ 1.5VDC batteries or AC - DC 9V power adapter
Power Consumption
Meter: 300 mA DC; Clamp: 20 mA DC
Max. Conductor size
Clamp can accommodate up to 86 mm (3.4” ) diameter
Distributed by MicroDAQ.com, Ltd. www.MicroDAQ.com (603) 746-5524