Specifications

 

Function 

Range and Resolution 

Accuracy (of reading)

199.9 ACA 

AC Current 

600 ACA 

AC Voltage 

600 VAC 

 

± (1.5% + 4 digits) 

@ 50/60Hz 

DC Voltage 

600 VDC 

± (1.0% + 1 digits) 

Resistance 

1999 

 

± (1.0% + 2 digits) 

  

Jaw size 

Opening 1.3" (33mm) approx. 

Display  

3-1/2 digits (2000 counts) LCD

 

Continuity 

Audible tone < 40

 approx. 

AC bandwidth 

40Hz to 400Hz

 

Safety compliance 

IEC 1010-1 and VDE 0411 

Operating Temperature 

32 to 122

o

F (0 to 50

o

C)

 

Storage Temperature

 

-4 to 140

o

F (-20 to 60

o

C) 

Over voltage

   

Cat II 600V 

Overload protection 

250V AC/DC Spark Gap protection; 

 

 

 

PTC protection for 

 range to 250V

 

Battery

   

 

9V battery (IEC 6F22) 

Auto Power OFF 

After 10 minutes of inactivity 

Dimensions/Weight

 

8x3.2x1.7" (204x80x43mm)/0.62 lbs. (281g) 

Safety 

For indoor use and in accordance with 
Overvoltage Category II, Pollution Degree 2. 
Category II includes local level, appliance, 
portable equipment, etc., with transient 
overvoltages less than Overvoltage Cat. III. 

Summary of Contents for 38387

Page 1: ...r s Guide 600A AC Clamp Meter Model 38387 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com Back to the Extech 38387 Product Info Page ...

Page 2: ...eed the maximum allowable input range of any function Do not apply voltage to meter when resistance function is selected Set the function switch OFF when the meter is not in use Remove the battery if meter is to be stored for longer than 60 days WARNINGS Set function switch to the appropriate position before measuring When measuring volts do not switch to current resistance modes Do not measure cu...

Page 3: ... greater than 25VAC rms or 35VDC These voltages are considered a shock hazard Remove the battery if the meter is to be stored for long periods Always discharge capacitors and remove power from the device under test before performing Diode Resistance or Continuity tests Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed elec...

Page 4: ...1 and VDE 0411 Operating Temperature 32 to 122 o F 0 to 50 o C Storage Temperature 4 to 140 o F 20 to 60 o C Over voltage Cat II 600V Overload protection 250V AC DC Spark Gap protection PTC protection for Ω range to 250V Battery 9V battery IEC 6F22 Auto Power OFF After 10 minutes of inactivity Dimensions Weight 8x3 2x1 7 204x80x43mm 0 62 lbs 281g Safety For indoor use and in accordance with Overvo...

Page 5: ...in the safety section of this operation manual prior to using this meter Set the function select switch to the OFF position when the meter is not in use AC DC Voltage Measurements 1 Insert the black test lead into the negative COM terminal and the red test lead into the positive V terminal 2 Set the function switch to the AC or DC voltage range position ACV or DCV 3 Connect the test leads in paral...

Page 6: ...t to disconnect one side of the device under test so the rest of the circuit will not interfere with the resistance reading 4 For Resistance tests read the resistance on the LCD display 5 For Continuity tests if the resistance is 40Ω a tone will sound Data Hold To freeze the LCD meter reading press the data hold button The data hold button is located on the left side of the meter top button While ...

Page 7: ...oth and mild detergent do not use abrasives or solvents If the meter is not to be used for periods of longer than 60 days remove the battery and store it separately Battery Replacement 1 Remove the three rear Phillips head screws 2 Open the battery compartment 3 Replace the 9V battery 4 Re assemble the meter 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us...

Reviews: