background image

407113-EN v3.6   4/14 

8

Warranty

FLIR Systems, Inc. warrants this Extech Instruments brand device

to be free of defects in parts and workmanship for

one year

from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the

instrument for service during or beyond the warranty period, contact the Customer Service Department for authorization. Visit

the website

for contact in formation. A Return Authorization (RA) number must be issued before any product is

returned. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit.

This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of
specification, improper maintenance or repair, or unauthorized modification. FLIR Systems, Inc. specifically disclaims any implied

warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or

consequential damages.

’

FLIR s total liability is limited to repair or replacement of the product. The warranty set forth above is

inclusive and no other warranty, whether written or oral, is expressed or implied.

Calibration, Repair, and Customer Care Services

FLIR Systems, Inc. offers repair and calibration services

for the Extech Instruments products we

sell. NIST certification for most products is also provided. Call the Customer Service Department for
information on calibration services available for this product. Annual calibrations should be

performed to verify meter performance and accuracy. Technical support and general customer
service is also provided, refer to the contact information provided below.

Copyright

©

2014 FLIR Systems, Inc.

All rights reserved including the right of reproduction in whole or in part in any form

Support Lines: U.S.

Technical Support: Option 3; E mail:

Repair & Returns: Option 4; E mail:

Product specifications are subject to change without notice

Please visit our website for the most up to date information

FLIR Commercial Systems, Inc.

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

Summary of Contents for 407113

Page 1: ...User Guide Heavy Duty CFM Thermo Anemometer Model 407113 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 2: ...n and CFM ft 3 min Temperature C and F Data Hold Freezes displayed reading Sampling rate One 1 reading per second Sensors Air velocity flow sensor Metal angled vane arms with low friction ball bearing Temp Sensor Precision thermistor MIN MAX Records Recalls lowest and highest readings Auto Power OFF Automatic shut off after 15 minutes PC Interface RS 232 Serial Communications 16 bit data stream Ov...

Page 3: ...iles per hour 1 1 78 3 mph 0 1 mph 2 0 4m h knots nautical miles per hour 1 0 to 68 knots 0 1 knots 2 0 4knots Air Flow Measurements Range Resolution Area CMM cubic meters per minute 0 999 900 m 3 min 0 001 to 100 0 to 9 999m 2 CFM cubic feet per minute 0 999 900 ft 3 min 0 001 to 100 0 to 9 999ft 2 Air Temperature Range Resolution Accuracy 32 to 175 o F 0 to 80 o C 0 1 o F C 1 5 o F 0 8 o C www G...

Page 4: ...nterface jack 3 LCD Display 4 Vane 5 Rubber Holster 6 Keypad 7 Battery compartment rear Note To access the rear battery compartment first remove the rubber holster that jackets the meter www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 5: ...when the display is in Data Hold mode 3 Press HOLD again to return to normal operation Maximum and Minimum Recording The 407113 allows the user to record and view the highest MAX and lowest MIN readings 1 Press the RECORD RECALL button once The REC indicator will appear on the display and the meter will begin recording the MAX and MIN values 2 Press the RECORD RECALL button to stop the MAX MIN rec...

Page 6: ...e The temperature function is not active in the FLOW mode 2 3V MAX Flow Mode In this mode the meter will display two thirds the measured Flow Volume To access this mode ensure that the meter is in the FLOW mode via the FLOW VELOCITY button and then press the FLOW MODE button until the 2 3V MAX display icon appears Now the Flow display will be 2 3 the actual measurement To return to the normal disp...

Page 7: ...ations NOTE Measurements made in inches must be converted to feet or meters before using the above formulae Unit of Measure Conversion Table m s ft min knots km h MPH 1 m s 1 196 87 1 944 3 6 2 24 1 ft min 0 00508 1 0 00987 0 01829 0 01138 1 knot 0 5144 101 27 1 1 8519 1 1523 1 km h 0 2778 54 69 0 54 1 0 6222 1 MPH 0 4464 87 89 0 8679 1 6071 1 Width W Height H Area A Width W x Height H CFM ft3 min...

Page 8: ...r any direct indirect incidental or consequential damages FLIR s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Calibration Repair and Customer Care Services FLIR Systems Inc offers repair and calibration services for the Extech Instruments products we sell NIST certi...

Page 9: ... conséquent direct indirect ou accidentel La responsabilité totale de FLIR est limitée à la réparation ou au remplacement du produit La garantie définie ci dessus est inclusive et aucune autre garantie écrite ou orale n est exprimée ou implicite Calibrage réparation et services après vente FLIR Systems Inc offre des services de calibrage et de réparation pour les produits Extech Instruments que no...

Page 10: ...sito determinado y no será responsable por cualesquier daños directos indirectos incidentales o consecuentes La responsabilidad total de FLIR está limitada a la reparación o reemplazo del producto La garantía precedente es inclusiva y no hay otra garantía ya sea escrita u oral expresa o implícita Servicios de calibración reparación y atención a clientes FLIR Systems Inc ofrece servicios de reparac...

Reviews: