IR Measurement Notes 

1.  The object under test should be larger than the spot (target) size calculated by the field 

of view diagram (printed on the side of the meter and in this guide). 

2.  Before measuring, be sure to clean surfaces that are covered with frost, oil, grime, etc. 
3.  If an object's surface is highly reflective, apply masking tape or flat black paint to the 

surface before measuring. Allow time for the paint or tape to adjust to the temperature 
of the surface it is covering. 

4.  Measurements through transparent surfaces such as glass will not be accurate. 
5.  Steam, dust, smoke, etc. can obscure measurements. 
6.  The meter automatically compensates for deviations in ambient temperature. However, 

it can take up to 30 minutes for the meter to adjust to extremely wide changes. 

7.  To find a hot spot, aim the meter outside the area of interest then scan across (in an up 

and down or side to side motion) until the hot spot is located. 

 
 
 
Field of View 

The meter’s field of view is 50:1. For example, if the meter is 50 inches from the target 
(spot), the diameter of the target must be greater than 1 inch. Other distances are shown in 
the field of view diagram. Measurements should normally be made as close as possible to 
the 1” spot distance. The meter can measure from longer distances, but the measurement 
may be affected by external sources of light. In addition, the spot size may be so large that 
it encompasses surface areas not intended to be measured. 

@50”

1”

@25”

0.5”

@100”

2”

@150cm

2.5cm

@300cm

5cm

@75cm

1.25cm

Summary of Contents for 42570

Page 1: ...User Manual Dual Laser InfraRed IR Thermometer MODEL 42570 ...

Page 2: ...at 781 890 7440 ext 210 for authorization or visit our website at www extech com click on Contact Extech and go to Service Department to request an RA number A Return Authorization RA number must be issued before any product is returned to Extech The sender is responsible for shipping charges freight insurance and proper packaging to prevent damage in transit This warranty does not apply to defect...

Page 3: ...USB port side DISPLAY 1 SCAN measurement in progress 2 Bargraph 3 Laser pointer active 4 Power locked ON 5 HOLD last measurement locked in display 6 Max Min temperature display or memory location display 7 Main temperature display 8 High Low limit alarm 9 USB connection 10 Battery status 11 Emissivity or Type K or Stored value display 12 Thermocouple probe installed 13 Emissivity setting 14 Logged...

Page 4: ...easured values LOG A memory location is displayed in the small upper display and the value in that location is displayed in the small lower display Press the or buttons to scroll through the locations TK With a Type K thermocouple probe connected to the meter the probe temperature is displayed in the small lower display With the trigger released HOLD displayed Press the MODE button to scroll throu...

Page 5: ...ODE button The setting is stored and memory and will remain as the turn on condition until changed Temperature Units The temperature units can be set to F or C The selection is made using the MODE button Lock feature The LOCK feature disables the Auto Power Off feature for the period of use when selected The feature is useful for long term temperature monitoring and hands free use The meter will r...

Page 6: ...ecorded temperature will appear in the lower right corner 4 To select another log location press the up and down keys Recalling Data To recall stored data after the unit shuts off 1 Press the MODE button until LOG appears in the lower left corner A LOG location number will be shown below LOG and the stored temperature for that location will be display 2 To move to another LOG location press the UP...

Page 7: ...mpensates for deviations in ambient temperature However it can take up to 30 minutes for the meter to adjust to extremely wide changes 7 To find a hot spot aim the meter outside the area of interest then scan across in an up and down or side to side motion until the hot spot is located Field of View The meter s field of view is 50 1 For example if the meter is 50 inches from the target spot the di...

Page 8: ... F 1 o C whichever is greater Thermocouple Thermometer Type K Range 50 to 1370 C 58 F to 2498 F Resolution 0 1 C 0 1 F 1000 1 C 1 F 1000 Accuracy 50 to 1000 C 58 to 1832 F 1 5 of reading 3 C 5 F 1000 to 1370 C 1832 F to 2498 F 1 5 of reading 2 C 3 6 F General Specifications Display Backlit LCD display with function indicators Response time 100ms Over range indication Operating Temperature 32 o F t...

Page 9: ...ject to change without notice For the latest version of this User s Guide Software updates and other up to the minute product information visit our website www extech com Extech Instruments Corporation 285 Bear Hill Rd Waltham MA 02451 Copyright 2009 Extech Instruments Corporation a FLIR company All rights reserved including the right of reproduction in whole or in part in any form ...

Reviews: