45170 –EU-EN-V1.2-5/11 

Data Hold 

Press the 

HOLD

 button to freeze the reading in the display. The 'HOLD' icon will appear on the 

upper right-hand side of the display. Press the HOLD button again to return to normal operation (the 
'HOLD' hold icon will disappear). 

Auto Power OFF 

The meter will automatically turn off after 10 minutes if no keys are pressed during this period. Auto 
power off is disabled in the max/min recording mode. 

Turning Power OFF 

Press the power button to turn power off. 
 

You, as the end user, are legally bound (

EU Battery ordinance

) to return all used 

batteries, 

disposal in the household garbage is prohibited! 

You can hand over your 

used batteries / accumulators at collection points in your community or wherever batteries 
/ accumulators are sold! 

Disposal: 

Follow the valid legal stipulations in respect of the disposal of the device at the 

end of its lifecycle 

 

 
 
 

Useful Equations 

Area equations 

 

 

 

Cubic equations 

CFM (ft

3

/min) = Air Velocity (ft/min) x Area (ft

2

CMM (m

3

/min) = Air Velocity (m/sec) x Area (m

2

) x 60

 

A = pi x R

2

R

A = W x H

W

H

Summary of Contents for 45170

Page 1: ...User s Guide 4 in 1 Humidity Temperature Airflow and Light Meter Model 45170 ...

Page 2: ...ht Meter With careful use this meter will provide years of reliable service Meter Description 1 Vane Airflow Sensor 2 Type K Thermocouple Input Jack 3 Display 4 Power Button 5 Unit Zero Button 6 C F Lux Ft cd Button 7 Light Sensor 8 RH and Air Temperature Sensors 9 Hold Button 10 Max Min Button 11 Function Button 1 2 3 4 5 6 7 8 9 10 11 ...

Page 3: ...is connected or if the thermocouple is defective the meter will display Primary display temperature will only work if a thermocouple is connected D Light Measurements 1 Press the Function button to select the Light Meter mode The light values are displayed and orientated 180 from the other functions for easy use 2 Press the Lux Ft cd to select Lux or Footcandle units of measure 3 Before making mea...

Page 4: ...ing mode Turning Power OFF Press the power button to turn power off You as the end user are legally bound EU Battery ordinance to return all used batteries disposal in the household garbage is prohibited You can hand over your used batteries accumulators at collection points in your community or wherever batteries accumulators are sold Disposal Follow the valid legal stipulations in respect of the...

Page 5: ...Humidity 10 0 to 95 0 0 1 4 RH from 10 to 70 RH 4 rdg 1 2 RH 70 RH 0 to 2 200 Lux 1 Lux 1 800 to 20 000 Lux 10 Lux 0 to 204 0 Fc 0 1 Fc Light Auto Ranging 170 to 1 860 Fc 1 Fc 5 rdg 8 digits General Specifications Display 4 digit 9999 count Dual Display LCD Sensors Thin film capacitance humidity sensor Min Max Min Max recalls the highest lowest reading Data Hold Data Hold freezes the display Opera...

Reviews: