Safety Precautions 

The 461750 incorporates a finger guard for protection. However, care should be taken when 
measuring surface speed to avoid injury. 

1.  Hold the meter firmly when touching the wheel or attachment to a moving object 

2.  Keep fingers behind the finger guard while taking measurements 

3.  Keep your eyes and attention on the measurement activity at all times 

4.  Do not attempt to record measurements while holding the meter to the moving object (use the 

Data Hold feature to freeze the reading on the LCD; refer to the Data Hold section of this 
manual). 

 

Meter Power 

Power ON / OFF 

1.  Press the triangular POWER HOLD button to turn the device ON. Alternatively, press the button 

at the bottom of the meter (just under the LCD) which doubles as a power on/off button. Two 
buttons are provided for easy reach at any holding angle. 

2.  Press and hold the triangular POWER HOLD button (or the alternate button) for approx. 5 

seconds to turn the device OFF. 

 

Auto Power OFF 

1.  The meter turns off AUTOMATICALLY after 20 minutes. 

2.  For 461750 only: To disable this feature, turn the meter off. Then press and hold the POWER 

and UNITS buttons until the meter turns on. Rel

ease the POWER button first and the ‘n’ display 

icon will appear. This indicates that the feature is disabled. 

 

Never dispose of used batteries or rechargeable batteries in household waste.  
As consumers, users are legally required to take used batteries to appropriate 
collection sites, the retail store where the batteries were purchased, or wherever 
batteries are sold.  

 

Disposal: 

Do not dispose of this instrument in household waste. The user is obligated to 

take end-of-life devices to a designated collection point for the disposal of electrical and 
electronic equipment. 

 

Summary of Contents for 461750

Page 1: ...User Manual Mini Contact Tachometer Model 461750 ...

Page 2: ...ls Careful use of this tachometer will provide years of reliable service Meter Description 1 RPM adaptor 2 Wheel for linear surface measurements 3 Adaptor shaft 4 Adapter socket 5 Hand Guard 6 Power ON OFF and HOLD button 7 Unit of measure selection button 8 LCD Display 9 Alternate Power ON OFF button Note that the battery compartment is located on the rear of the instrument Display Description 1 ...

Page 3: ... power on off button Two buttons are provided for easy reach at any holding angle 2 Press and hold the triangular POWER HOLD button or the alternate button for approx 5 seconds to turn the device OFF Auto Power OFF 1 The meter turns off AUTOMATICALLY after 20 minutes 2 For 461750 only To disable this feature turn the meter off Then press and hold the POWER and UNITS buttons until the meter turns o...

Page 4: ...achment that best fits the application to the meter shaft as shown below 2 Turn the meter ON 3 Use the UNITS button to select RPM the display will reflect the selection 4 Touch the attachment to the moving object and read the displayed measurement Rotating Wheel Touch the convex or concave attachment to the turning object ...

Page 5: ... be pressed and released to activate Data Hold Data Hold automatically freezes the displayed reading While the reading is held the HOLD display icon switches on Press the POWER HOLD button again to exit this mode Maintenance Battery Replacement When the 9V battery weakens the low battery indicator appears on the LCD To replace the battery open the rear compartment and exchange the battery Be sure ...

Page 6: ... 50o C Operating Humidity 80 RH Max Power supply 9V Battery Battery Life 40 hours approx Applicable standards EN 50081 1 1992 EN 55022 EN 50082 1 1997 EN 55024 Dimensions 5 9 x 2 0 x 1 3 150 x 51 x 33mm Weight 5 0 oz 142g Range Specifications Measurement Range Accuracy Rotation 10 000 to 9999 rpm 0 1 reading 2 digits Surface Speed 3 0000 to 6560 0 ft min 1 5 reading 2digits Surface Speed 1 0000 to...

Page 7: ...alibration for most of our products Contact us for information on calibration and repair availability refer to the contact information below Annual calibrations should be performed to verify meter performance and accuracy Product specifications are subject to change without notice Please visit our website for the most up to date product information www extech com Contact Customer Support Customer ...