AUT500-EU-EN v1.0 5/13
15
Function Range Resolution
Accuracy
Frequency
4.000Hz 0.001Hz
(1.5% r 5 digits)
40.00Hz 0.01Hz
400.0Hz 0.1Hz
(1.2% r 2 digits)
4.000MHz 0.001kHz
40.00MHz 0.01kHz
Sensitivity: >5V RMS up to 40MHz and >15 VRMS over 40MHz
Duty Cycle
0.5 to 99.9%
0.1%
(2.0% r 5 digits)
Pulse width: 100µs to 100ms; Frequency: 5Hz to 100kHz; Sensitivity: >5V RMS
RPM 4
(tachometer)
600 to 4000 RPM
1 RPM
(2.0% r 4 digits)
1000 to 12000 x10 RPM
10 RPM
RPM 2/DIS
300 to 4000 RPM
1 RPM
1000 to 6000 x10 RPM
10 RPM
Effective Reading >600V
DWELL ANGLE
4 CYL 0 to 90.0
o
0.1
o
(2.0% r 4 digits)
5 CYL 0 to 72.0
o
6 CYL 0 to 60.0
o
8 CYL 0 to 45.0
o
NOTES:
Accuracy is stated at 18
o
C to 28
o
C (65
o
F to 83
o
F) and less than 75% RH
Accuracy specifications consist of two elements:
(% reading) – This is the accuracy of the measurement circuit.
(+ digits) – This is the accuracy of the analog to digital converter.