background image

Specifications 

Measurement range 

0-999 ppm

Resolution 

1 ppm 

Accuracy 

 0 ~ 100 ppm: ± 20%
100 ~ 500 ppm: ± 15%

Accuracy stated for ambient 
conditions: 20

o

C ±5

o

C (68

o

F ±9

o

F) 

and 50% RH ±20%RH

Sensor Type 

Electrochemical 

Power supply 

(3) 1.5V ‘AAA’ batteries

Battery life 

Approx. 250 hours (backlight
off); 35 hours (backlight on)

Dimensions / Weight: 

175 x 47 x 28mm (6.9 x 1.8 x
1.1”) / 158.8g (5.6 oz.)

Troubleshooting 

Error  

Problem 

Solution 

Display 

No display when pressing 
power button 

Ensure batteries are 
properly installed with 
correct polarity 

Replace batteries 

Display 

Display switches off 

Check for low battery 
indicator; replace 
batteries 

Display 

Calibration Failure 

Check for low battery 
indicator; replace 
batteries 

E2 

Measurement is below 
the range of the meter 

Check readings in a 
different area 

E3 

Measurement is above 
the range of the meter 

Check readings in a 
different area 

E4 

Data error 

Contact Extech for service 

E31 

A/D failure  

Contact Extech for service 

E33 

Measurement circuit 
failure 

Contact Extech for service 

E35 

Self-test failure 

Power meter in an area 
free of carbon monoxide  

Sensor Failure 

Contact Extech for service 

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

Visit us at www.T

estEquipmentDepot.com

Summary of Contents for C015

Page 1: ...EXT J f User Manual Carbon Monoxide Meter Model C015 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Page 2: ... and translations of this User Manual Product Updates and Customer Support Features Adjustable carbon monoxide warning level Dual Display Long life electrochemical sensor Audible alarm Backlit LCD for easy viewing in dimly lit areas Low battery indicator Auto power off Included wrist strap and carry pouch Safety Information IMPORTANT SAFETY NOTES The CO15 Carbon Monoxide Monitor is intended for ge...

Page 3: ...ture and in an area free of CO If not the meter will read incorrectly when subsequently measuring CO 0 1 PPM Normal background levels 9 PPM Maximum allowable short term exposure 50 PPM Maximum allowable continuous exposure level in any 8 hour period according to OSHA 200 PPM Mild headache fatigue nausea and dizziness after 2 3 hours 400 PPM Frontal headache with 1 2 hours life threatening after 3 ...

Page 4: ...3 4 3 1 Q Turn the meter on and off short press Select alarm setpoint value long press from a powered OFF state release the button when desired alarm limit is displayed Turn the backlight on and off short press Toggle temperature units long press during self test period Reset Maximum CO value long press in normal operating mode 4 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1...

Page 5: ... environment and displays the reading in parts per million PPM in the primary display 1 To take a measurement trace the CO15 around the area of the suspected leak 2 The meter indicates the presence of carbon monoxide CO in PPM in the primary display The secondary display indicates the maximum value since powered on 3 Long press the backlight button while in measurement mode to reset the maximum va...

Page 6: ......

Page 7: ...y Replace batteries Display Display switches off Check for low battery indicator replace batteries Display Calibration Failure Check for low battery indicator replace batteries E2 Measurement is below the range of the meter Check readings in a different area E3 Measurement is above the range of the meter Check readings in a different area E4 Data error Contact Extech for service E31 A D failure Co...

Reviews: