Introduction 

This process calibrator/meter is a hand-held, battery-operated instrument for testing and 
troubleshooting power electronic systems. This device can be used not only for instrument 
system maintenance, but also for maintaining, servicing industrial meters, testing electronic 
circuits and electronic equipments. The meter can also be used to measure or calibrate 
sensors or transmitters in automotive or automatic control system. 
 
The meter generates a high precision constant voltage, constant current and square wave 
output and includes a full feature, high accuracy multimeter. The precision source and the 
measurement functions can perform simultaneously.   
   

Main Features: 

 

 

Generates and Measures Signal simultaneously 

 

1,200

 drive capability with special yellow lead for 20mA simulation 

 

High precision Constant voltage, Constant Current and Square wave outputs   

 

Intelligent Output and Standby control 

 

Built-in Ni-MH rechargeable battery 

 

Smart Charger design without battery removal   

 

Brightness EL backlight   

 

Coarse or Fine output adjust 

 

The % scale readout for 4-20mA or 0-20mA   

 

Adjustable steps and time interval for Auto Scan 

 

Adjustable resolutions and start for linear Ramp output 

 

1ms Peak hold to capture inrush voltage and current easily   

 

Temperature test with the option of 0

°

C compensation 

 

Frequency, Duty cycle and Pulse width measurements   

 

Dynamic Recording for MIN/MAX/AVG   

 

Data Hold with Manual or Auto Trigger and Relative modes   

 

Diode and Audible Continuity test 

 

Bi-directional optical computer interface with SCPI commands 

 

Safe, precise and fast closed-case calibration     

 

50,000 count precision True-RMS digital multi-meter and designed to meet IEC-1010 
CAT. II 250V standards 

 
 
 

 

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

 

Visit us at www.T

estEquipmentDepot.com

Back to the 

Extech CMM-17 Product 

Page

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

FAX 781.665.0780 - TestEquipmentDepot.com 

Summary of Contents for CMM-17

Page 1: ...kHz 4 200 20 µ m sec AV µ m sec AV AUTO Quick Start CMM 17 Process Calibrator Multimeter Constant Voltage mA Source Square Wave Auto Scan Ramp Dual Display Multimeter Rechargeable Batteries This guide provides an overview of the meter For more detailed information refer to the CMM 17 User s Guide provided with the meter ...

Page 2: ...Output and Standby control Built in Ni MH rechargeable battery Smart Charger design without battery removal Brightness EL backlight Coarse or Fine output adjust The scale readout for 4 20mA or 0 20mA Adjustable steps and time interval for Auto Scan Adjustable resolutions and start for linear Ramp output 1ms Peak hold to capture inrush voltage and current easily Temperature test with the option of ...

Page 3: ...ure Voltage when the current measurement is selected Do not use this device if it looks damaged Inspect the leads for damaged insulation or exposed metal Replace damaged leads Disconnect the power and discharge all high voltage capacitors before testing in the resistance continuity and diode function Use caution when working above 70V DC or 33V RMS and 46 7V peak these voltages may cause a shock h...

Page 4: ...inals to the device to be tested 6 Press the OUTPUT button The process signal will become active 7 Press the OUTPUT button to return the output to the standby mode Figure 1 Quick Output Operation WARNING Read SAFETY INFORMATION before using this 1 Set switch to M S side 2 Turn the function switch to select combined function 3 Press SHIFT for output setting 4 Use the arrow buttons to set the output...

Page 5: ...entarily to select AC voltage measurement 4 Press the Dual button momentarily to set frequency measuring on secondary display 5 Connect the INPUT terminals by test leads to the source to be tested Figure 2 ACV Hz Measurement 1 Set switch to M or M S side 2 Turn the function switch to V function 3 Press momentarily to select AC voltage test 4 Press momentarily to set frequency measuring on secondar...

Page 6: ...utput for 8 Square wave output for mS 9 Output input units 10 Scan output 11 Ramp output 12 Shift button operation 13 Diode audible continuity 14 Auto range 15 Relative mode 16 Low battery 17 Auto power off icon 18 Data Hold manual trigger 19 Primary display for input 20 Input units 21 Positive negative trigger slope for and mS tests 22 Without ambient temperature compensation 23 4 20 4 20mA 24 0 ...

Page 7: ...n operation for INPUT OFF or OUTPUT ON Press and hold for more than 1 sec to toggle backlit ON OFF Hz Select Hz and Pulse width tests on Primary display Press and hold for more than 1 sec to exit HOLD Freeze existing measured value Press again to trigger next measuring value Press and hold for more than 1sec to exit data trigger hold REL Set the value on the display to be subtracted C F Press and ...

Page 8: ...d output MODE Select output modes for CV CC SCAN and RAMP Select Hz pulse width and Level adjustments for Square wave output SHIFT Press to shift button operation for INPUT OFF or OUTPUT ON Press and hold for more than 1 sec to toggle backlit ON OFF 5 UP 6 DOWN Adjust digit or polarity Press momentarily to increase decrease 1 count for present digit or toggle the polarity of output state M S Provi...

Page 9: ...rements Constant voltage 1 5V 15V 3 DC AC or DC AC mV measurements Constant voltage 1 5V 15V 4 Resistance Continuity measurements Constant voltage 1 5V 15V 5 Diode Audible Continuity Constant current 25 mA Constant voltage 1 5V 15V Constant current 25 mA 6 DC AC or DC AC mA measurements 50mA and 500 mA Square wave output Output and Input Terminals Figure 8 Output Input Terminals 1 2 3 6 5 4 OUTPUT...

Page 10: ...4800 9600 and 19200 Parity None Odd even or none Data bit 8 8 bits or 7 bits Stop bit is always 1 bit ECHO OFF ON or OFF Printer Only OFF ON or OFF Percentage scale 4 20mA 4 20mA and 0 20mA for scale readout Frequency 0 5Hz Set minimum measuring frequency 0 5 1 or 2 Hz Beeper 4800 The driving frequency can be set for 4800 2400 1200 or 600 Hz OFF disables the beeper Temperature C F Four combination...

Reviews: