Introduction 

Congratulations on your purchase of this Extech MA250 Clamp Meter. This meter measures AC 
Current, AC/DC Voltage, Resistance, Capacitance, Frequency, Diode Test, Duty Cycle and Continuity. 
Special features include Thermocouple Temperature and Non-Contact Voltage detection. The double 
molded case is designed for heavy duty use. This meter is shipped fully tested and calibrated and, with 
proper use, will provide years of reliable service. 

Safety 

International Safety Symbols 

This symbol, adjacent to another symbol or terminal, indicates the user must refer 
to the manual for further information. 
 
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous 
voltages may be present 
 
Double insulation 

 

This 

WARNING

 symbol indicates a potentially hazardous situation, which if not 

avoided, could result in death or serious injury. 

This 

CAUTION

 symbol indicates a potentially hazardous situation, which if not 

avoided, may result damage to the product. 

 
 
 

PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY 

OVERVOLTAGE CATEGORY I 

Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which 
measures are taken to limit the transient overvoltages to an appropriate low level. 

Note – Examples include protected electronic circuits. 

OVERVOLTAGE CATEGORY II 

Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from 
the fixed installation. 

Note – Examples include household, office, and laboratory appliances. 

OVERVOLTAGE CATEGORY III 

Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations. 

Note – Examples include switches in the fixed installation and some equipment for industrial use with 
permanent connection to the fixed installation. 

OVERVOLTAGE CATEGORY IV 

Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation. 

Note – Examples include electricity meters and primary over-current protection equipment

 

WARNING 

CAUTION 

contact:

sale@ponpe.com

www.ponpe.com

Summary of Contents for MA250

Page 1: ...User s Guide 200Amp AC Clamp Meter NCV Model MA250 www ponpe com contact sale ponpe com...

Page 2: ...ol indicates a potentially hazardous situation which if not avoided may result damage to the product PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLTAGE CATEG...

Page 3: ...replacing the battery or fuses Inspect the condition of the test leads and the meter itself for any damage before operating the meter Repair or replace any damage before use Use great care when making...

Page 4: ...mpartment rear 13 Positive input jack Display icons Description HOLD Data Hold AUTO Autoranging DC Direct Current AC Alternating Current Low battery REL Relative V Volts Voltage Ohms Resistance A Ampe...

Page 5: ...n on with a steady red light NOTE The conductors in electrical cord sets are often twisted For best results move the probe tip along a length of the cord to assure placing the tip in close proximity t...

Page 6: ...s the Hz button to display Frequency 7 Press the Hz button to display Duty Cycle Resistance Diode Continuity Measurements Note Remove power from the device under test before making resistance measurem...

Page 7: ...uch the black test probe tip to one side of the device Touch the red test probe tip to the other side of the device 4 Read the capacitance value in the display Type K Temperature Measurements 1 Rotate...

Page 8: ...utoranging is disabled and measurements are limited to the range active when the REL button was pressed Press the REL button to exit the mode Note Relative does not function in Frequency or Duty Cycle...

Page 9: ...nd store it separately Battery Replacement 1 Remove the 2 Phillips head screws that secures the rear battery cover 2 Open the battery compartment 3 Replace the 2 AAA batteries 4 Secure the battery com...

Page 10: ...igits 400 0 0 1 1 0 4 digits 4 000k 0 001k 40 00k 0 01k 400 0k 0 1k 1 5 2 digits 4 000M 0 001M 2 5 3 digits Resistance 40 00M 0 01M 3 5 5 digits 40 00nF 0 01nF 4 0 20 digits 400 0nF 0 1nF 40 00 F 0 01...

Page 11: ...re 5 C to 40 C 41 F to 104 F Storage Temperature 20 C to 60 C 4 F to 140 F Operating Humidity Max 80 up to 31 C 87 F decreasing linearly to 50 at 40 C 104 F Storage Humidity 80 Operating Altitude 2000...

Reviews: