Introduction 

Congratulations on your purchase of this Extech MA435T True RMS Clamp Meter. This meter 
measures AC/DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency, Diode Test, Duty 
Cycle and Continuity. Special features include Thermocouple Temperature and Non-Contact Voltage 
detection. The double molded case is designed for heavy duty use. This meter is shipped fully tested 
and calibrated and, with proper use, will provide years of reliable service. 

Safety 

International Safety Symbols 

This symbol, adjacent to another symbol or terminal, indicates the user must refer 
to the manual for further information. 
 
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous 
voltages may be present 
 
Double insulation 

 

This 

WARNING

 symbol indicates a potentially hazardous situation, which if not 

avoided, could result in death or serious injury. 

This 

CAUTION

 symbol indicates a potentially hazardous situation, which if not 

avoided, may result damage to the product. 

 
 
 

PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY 

OVERVOLTAGE CATEGORY I 

Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which 
measures are taken to limit the transient overvoltages to an appropriate low level. 

Note – Examples include protected electronic circuits. 

OVERVOLTAGE CATEGORY II 

Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from 
the fixed installation. 

Note – Examples include household, office, and laboratory appliances. 

OVERVOLTAGE CATEGORY III 

Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations. 

Note – Examples include switches in the fixed installation and some equipment for industrial use with 
permanent connection to the fixed installation. 

OVERVOLTAGE CATEGORY IV 

Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation. 

Note – Examples include electricity meters and primary over-current protection equipment

 

WARNING 

CAUTION 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

Summary of Contents for MA435T

Page 1: ...ER MANUAL 400Amp True RMS AC DC Clamp Meter Model MA435T Additional User Manual Translations available at www extech com www GlobalTestSupply com nd Quality Products Online at sales GlobalTestSupply c...

Page 2: ...potentially hazardous situation which if not avoided may result damage to the product PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLTAGE CATEGORY I is equip...

Page 3: ...fuses Inspect the condition of the test leads and the meter itself for any damage before operating the meter Repair or replace any damage before use Use great care when making measurements if the volt...

Page 4: ...on 13 V CAP TEMP Hz jack 14 Battery Cover rear Display icons Description HOLD Data Hold AUTO Autoranging DC Direct Current AC Alternating Current Low battery REL Relative V Volts Voltage Ohms Resistan...

Page 5: ...conductors in electrical cord sets are often twisted For best results move the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor NOTE The detector...

Page 6: ...isplay Frequency 7 Press the Hz button to display Duty Cycle Resistance Diode Continuity Measurements Note Remove power from the device under test before making resistance measurements 1 Set the funct...

Page 7: ...e of the device Touch the red test probe tip to the other side of the device 4 Read the capacitance value in the display Type K Temperature Measurements 1 Rotate the function switch to the F or C temp...

Page 8: ...lly selected perform the following 1 Press the RANGE button and the AUTO icon will turn of 2 Press the RANGE button to step through the available ranges until the range needed appears 3 Press and hold...

Page 9: ...ent 3 Replace the 9V battery 4 Secure the battery compartment door Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used bat...

Page 10: ...40 00k 0 01k 400 0k 0 1k 4 000M 0 001M 2 5 3 digits 40 00M 0 01M 3 5 5 digits Capacitance 40 00nF 0 01nF 4 0 20 digits 400 0nF 0 1nF 3 0 5 digits 4 000 F 0 001 F 40 00 F 0 01 F 100 0 F 0 1 F 4 0 10 di...

Page 11: ...104 F Storage Temperature 20 C to 60 C 4 F to 140 F Operating Humidity Max 80 up to 31 C 87 F decreasing linearly to 50 at 40 C 104 F Storage Humidity 80 Operating Altitude 2000meters 7000ft maximum B...

Reviews: