MA435T

en

GB_v1.4

   

10/16

 

3

SAFETY NOTES 

  Do not exceed the maximum allowable input range of any function. 

  Do not apply voltage to meter when resistance function is selected. 

  Set the function switch OFF when the meter is not in use. 

  Remove the battery if meter is to be stored for longer than 60 days.

 

WARNINGS 

  Set function switch to the appropriate position before measuring. 

  When measuring volts do not switch to current/resistance modes. 

  Do not measure current on a circuit whose voltage exceeds 600V. 

  When changing ranges always disconnect the test leads from the circuit under test. 

CAUTIONS 

  Improper use of this meter can cause damage, shock, injury or death. Read and understand 

this user manual before operating the meter. 

  Always remove the test leads before replacing the battery or fuses. 

  Inspect the condition of the test leads and the meter itself for any damage before operating the 

meter. Repair or replace any damage before use. 

  Use great care when making measurements if the voltages are greater than 25VAC rms or 

35VDC. These voltages are considered a shock hazard. 

  Always discharge capacitors and remove power from the device under test before performing 

Diode, Resistance or Continuity tests. 

  Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty 

of connection to the recessed electrical contacts. Other means should be used to ensure that 
the terminals are not "live". 

  If the equipment is used in a manner not specified by the manufacturer, the protection provided 

by the equipment may be impaired. 

 

Function Maximum 

Input 

AC/DC Amps,  

400A 

AC/DC Volts 

600V DC/AC 

Resistance, Capacitance, Frequency, Diode 
Test, Continuity, Temperature 

250V DC/AC 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

Summary of Contents for MA435T

Page 1: ...ER MANUAL 400Amp True RMS AC DC Clamp Meter Model MA435T Additional User Manual Translations available at www extech com www GlobalTestSupply com nd Quality Products Online at sales GlobalTestSupply c...

Page 2: ...potentially hazardous situation which if not avoided may result damage to the product PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLTAGE CATEGORY I is equip...

Page 3: ...fuses Inspect the condition of the test leads and the meter itself for any damage before operating the meter Repair or replace any damage before use Use great care when making measurements if the volt...

Page 4: ...on 13 V CAP TEMP Hz jack 14 Battery Cover rear Display icons Description HOLD Data Hold AUTO Autoranging DC Direct Current AC Alternating Current Low battery REL Relative V Volts Voltage Ohms Resistan...

Page 5: ...conductors in electrical cord sets are often twisted For best results move the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor NOTE The detector...

Page 6: ...isplay Frequency 7 Press the Hz button to display Duty Cycle Resistance Diode Continuity Measurements Note Remove power from the device under test before making resistance measurements 1 Set the funct...

Page 7: ...e of the device Touch the red test probe tip to the other side of the device 4 Read the capacitance value in the display Type K Temperature Measurements 1 Rotate the function switch to the F or C temp...

Page 8: ...lly selected perform the following 1 Press the RANGE button and the AUTO icon will turn of 2 Press the RANGE button to step through the available ranges until the range needed appears 3 Press and hold...

Page 9: ...ent 3 Replace the 9V battery 4 Secure the battery compartment door Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used bat...

Page 10: ...40 00k 0 01k 400 0k 0 1k 4 000M 0 001M 2 5 3 digits 40 00M 0 01M 3 5 5 digits Capacitance 40 00nF 0 01nF 4 0 20 digits 400 0nF 0 1nF 3 0 5 digits 4 000 F 0 001 F 40 00 F 0 01 F 100 0 F 0 1 F 4 0 10 di...

Page 11: ...104 F Storage Temperature 20 C to 60 C 4 F to 140 F Operating Humidity Max 80 up to 31 C 87 F decreasing linearly to 50 at 40 C 104 F Storage Humidity 80 Operating Altitude 2000meters 7000ft maximum B...

Reviews: